CV-L107CL
16
6.6.3.
Shutter-Select mode with Internal line rate generator
This mode allows the user to have full control of the line rate and the exposure time individually, by
programming separate timing generators. Subsequently the camera does not accept an external
trigger signal in this mode.
To use this mode:
Set function
Trigger mode, Shutter-Select
TR=1
Line rate
LR=52.6
μ
s to 53.683ms
Trigger origin, internal
TG=0
Individual R, G and B exposure
EI=0(individual)
EI=1(tracking with G)
Programmable exposure
PER/PEG/PEB=2 to 2150400 (in 25ns steps)
Important note:
If using individual exposure, the EEN signal represents the channel with the longest exposure time
Fig. 11 Shutter-Select mode with Internal line rate generator (and individual exposure)