CV-A50 IR
4. Camera Housing and Dimensions
Fig. 1. Locations and dimensions.
1.
12-pin Hirose connector for frame grabber interfacing and power (12V DC).
2.
BNC connector for video output. VS 1.0 Vpp 75 Ohm.
3.
6-pin Hirose connector for trigger input and RS-232C control interface.
4.
Gain potentiometer for manual gain setting.
5.
Mounting holes, 8 x M3. For precision mounting use only the 4 holes located at the
forward part of the bottom plate.
6.
1/2” interline-transfer type CCD sensor.
7.
Lens mount for C-mount lenses. *1)
Note *1): Rear protrusion on the C-mount lens must be less than 10mm (0.4 inches approx.).
When IR-cut filter is used, it must be less than 7.0 mm (0.28 inches approx.).
The IR-cut filter is placed in the C-mount thread.
The C-mount IR-cut filter must be ordered separately.
- 3 -