BM-141GE / BB-141GE
45
TriggerActivation
This can set how the trigger is activated.
RisingEdge: The trigger is effective at the rising edge of the pulse.
FallingEdge: The trigger is effective at the falling edge of the pulse.
ExposureMode
This can select the exposure mode.
Timed: The exposure is set in units of
μ
seconds or lines.
TriggerWidth: The exposure is the same as the trigger width.
The BM-141GE and BB-141GE have a JAI Acquisition and Trigger Control function which is the
same as used for previous models and includes 6 types of exposure modes.
Acquisition and Trigger Control and JAI Acquisition and Trigger Control are linked to each
other and if the one is set, the setting parameters are reflected in the other.
The following is an example: when JAI Acquisition and Trigger Control is set at EPS,
TriggerMode is automatically set ON and ExposureMode is set to Timed.
The exposure time can be set in the JAI Shutter Mode by selecting either lines or
microseconds and the setting values are reflected in the same items of Acquisition and
Trigger Control.
Содержание BM-141GE
Страница 5: ...BM 141GE BB 141GE 5 Change History 74 User s Record 75...
Страница 18: ...BM 141GE BB 141GE 18 Line Source 6 5 GPIO programming examples 6 5 1 Pulse generator setting sreen...
Страница 64: ...BM 141GE BB 141GE 64 11 4 7 Feature Properties Guru...
Страница 65: ...BM 141GE BB 141GE 65...
Страница 66: ...BM 141GE BB 141GE 66...
Страница 67: ...BM 141GE BB 141GE 67...