AT-030MCL
- 8 -
Port2 (Used for 30bits, 36bits)
Pin No
In/Out
Name
Note
1,26
Shield
DC GND
2(-),15(+)
O
TxOUT0
Data out
3(-),16(+)
O
TxOUT1
4(-),17(+)
O
TxOUT2
5(-),18(+)
O
TxClk
Clock for CL
6(-),19(+)
O
TxOUT3
Data out
7(+),20(-)
NC
8(-),21(+)
NC
9(-),22(+)
NC
10(+),23(-)
Reserved
13,14
Shield
DC GND
5.3. DIP switch SW-600
This switch can select ON or OFF of 75 ohm termination for trigger input.
The factory default setting is OFF which is TTL level.
SW-600 is located in the rear board.
No
Functions
Setting
ON
OFF
1
Trigger input termination
75
Ω
TTL
2
NC
-
-
5.4. Rear Panel indication
The rear panel mounted LED provides the following information:
Amber
: Power connected - initiating
Steady green : Camera is operating in Continuous mode
Flashing green : The camera is receiving external trigger
Fig.4. rear panel