AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Setting List (Feature Properties)
- 99 -
JAI CustomControlSensorMultiROI
Related Topic:
Configure settings for sensor Multi ROI.
Notes:
l
This function is only supported on AP-1600T-PMCL.
l
Settings that can only be configured when image acquisition on the camera is stopped.
SensorMultiROI
Control Item
Setting Range
Default
Description
SensorMultiRoiMode
Off
On
Off
Enable/disable sensor Multi Roi. *)This function can be
enabled only when SequecerMode is Off and
MultiRoiMode is Off.
SensorMultiRoiIndex
Index1
Index2
Index1
Select the index for the sensor Multi Roi mode.
SensorMultiRoiWidth
96 ~ 1456
-
Set the width for the selected sensor Multi Roi index.
SensorMultiRoiHeight 2 ~ 1088
-
Set the height for the selected sensor Multi Roi index.
SensorMultiRoiOffsetX
0 ~ 1440
The index 2 depends on the
setting value of index 1.
-
Set the horizontal offset for the selected sensor Multi Roi
index.
SensorMultiRoiOffsetY
0 ~ 1086
The index 2 depends on the
setting value of index 1.
0
Set the vertical offset for the selected sensor Multi Roi
index.
SensorMultiROI
HorizontalEnable
False
True
-
Enable / disable each SensorMultiRoiIndex.
SensorMultiROI
VerticalEnable
False
True
-
Enable / disable each SensorMultiRoiIndex.