Installation
Item no. 10405047-06, Revision 02
30 ( 48 )
8.4.3
Setting values
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
Ü
Keep to the following values:
Taper cleaning
4,5 - 6 bar
Pneumatic system for tool change
5,0 - 8,0 bar
8.5
Setting the internal coolant supply
1
Internal cooling (as required)
M5
Max. 10 bar
2
Internal cooling (as required)
M5
Max. 10 bar
3
Compressed air
10 bar: n = 0 rpm
4
Cooling lubricant
Max. 150 bar
Min. 1 bar (*)
5
Vent
6
Leakage
(*) Must be present at the connection of the internal coolant supply.