Technical description
Item no. 10303048, Revision 04
13 ( 40 )
5.4
Sealing air
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
The sealing air prevents foreign bodies such as chips and liquids (e.g. emul-
sions) from entering the HF spindle.
Ü
Check that air escapes at the front between the housing and the rotating
parts of the HF spindle.
5.5
Taper cleaning
Taper cleaning prevents chips and liquids from entering the shaft during a
tool change and causing contamination and damage to the inner taper and
the clamping system.
The taper cleaning is integrated in the pneumatics system for the tool change.
This means that no additional connections are required.
q
Blow air through collet during tool change
5.6
Pneumatic tool change
For guidelines on air quality,
see "Air purity classes (ISO
8573-1)
" section.
The tool change or tool taper change is performed pneumatically.
During this, a mechanism is operated inside the HF spindle which clamps, re-
leases, or ejects the tool taper or collet.
5.7
Cylinder vent
The cylinder takes in air when clamping the taper/tool. This air must be clean
and dry.