background image

Technical Specifications

Item no. 10205020, Revision 05

16 ( 36 )

Note: Damage due to incorrect performance data.

The values of the parameters relate exclusively to the motor.

u

HF spindle values: See tables S1-100%, S6-60% and S2-Pmax.

Parameter

*

Meaning

Value

Unit

p0304

Rated voltage (phase-phase)

380

Vrms

p0305

Rated current

14,3

Arms

p0307

Rated power

5,5

kW

p0308

Rated power factor

0,86

cos φ

p0310

Rated frequency

1.000

Hz

p0311

Rated speed

29.573

rpm

---

Rated power loss

1.072

W

---

Rated rotation speed

36.000

rpm

p0312

Rated torque

1,776

Nm

p0314

Motor poles (pairs)

2

---

p0320

Rated magnetization current

7,16

Arms

p0322

Maximum speed

42.000

rpm

p0326

Stalling torque correction factor

100

%

p0335

Cooling type

Liquid cooled

p0341

Moment of inertia

0,0013153

kgm²

p0348

Field weakening operating speed VDC=600V

32.128

rpm

p0350

Stator resistance, cold (strand)

0,224

p0353

Series inductance (strand)

0

mH

p0354

Rotor resistance, cold

2.428

p0356

Stator stray inductance

459

mH

p0358

Rotor stray inductance

458

mH

p0360

Main inductance

4,158

mH

p0604

Motor temperature warning threshold

91

°C

p0605

Motor temperature fault threshold

130

°C

p0640

Current limit

28

Arms

p1800

Pulse frequency

16

kHz

---

DC link voltage

600

VDC

---

Series capacitance

0

µF

---

Maximum voltage

V

---

Idle reduction

%

---

Stator stray reactance X1

2,995

---

Rotor stray reactance X2

3,033

---

Main field reactance Xh

26,27

(*) Parameters for Siemens SINAMICS 120

Содержание Z100-M536.03 S5

Страница 1: ...Manual Z100 M536 03 S5 High Frequency Spindle Manual taper change...

Страница 2: ...velopment we reserve the right to make technical modifications and variations from the exact design described in the manual The text in this manual has been compiled with the utmost care However Nakan...

Страница 3: ...peed sensor digital differential magneto resistor 19 6 6 Air borne noise emissions 20 7 Operating location 20 8 Installation 21 8 1 Installing the HF spindle 21 8 2 Diameter of media supply line 22 8...

Страница 4: ...of the man ual carefully again 1 2 Explanation of symbols used To enable quick classification of information this manual uses visual aids in the form of symbols and text markings Notes are marked with...

Страница 5: ...ional accessories Available on request q Spindle holder q Frequency converter q Chiller q Collet grease q Further accessories on request Only approved accessories have been tested for operational safe...

Страница 6: ...nd a frequency con verter 3 1 Permissible types of machining The HF spindle has been developed only for the following types of machining q Cutting q Drilling q Engraving q Grinding Contact Nakanishi J...

Страница 7: ...re not approved for use in areas at risk of explosion Use in such areas may result in explosions u Do not use the HF spindle in potentially explosive atmospheres DANGER Due to flying parts The HF spin...

Страница 8: ...ay cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always wear protective goggles during work Example of design Inserting the shank Note Ensure...

Страница 9: ...the machine controller for evaluation 4 3 Installation and maintenance Carry out installation cleaning and maintenance work only after shutting down the HF spindle and after the shaft has come to a s...

Страница 10: ...Technical description Item no 10205020 Revision 05 10 36 5 Technical description 5 1 Connections of HF spindle 2 1 3 2 1 Electrical connection 2 Cooling water G 1 4 3 Sealing air G 1 8...

Страница 11: ...the machine con troller Note Connect the SpeedTEC quick locking connector u For the combination SpeedTEC connector plug SpeedTEC cable plug u Remove the O ring on the SpeedTEC connector plug 5 3 Cooli...

Страница 12: ...Motor poles pairs 2 Rated rotation speed 36 000 rpm Acceleration braking value Per second 10 000 rpm other values by consultation Characteristics Speed sensor Differential magneto resistor TTL Number...

Страница 13: ...Technical Specifications Item no 10205020 Revision 05 13 36 6 1 Dimensions Clamping range...

Страница 14: ...tion speed 5 000 10 000 15 000 20 000 25 000 30 000 36 000 rpm Speed 4 760 9 650 14 675 19 680 24 685 29 750 35 700 rpm Frequency 167 333 500 667 833 1 000 1 200 Hz Rated power 0 917 1 833 2 75 3 667...

Страница 15: ...0 12 10 kW Torque 4 7 4 7 4 1 4 1 4 1 3 9 2 8 Nm Voltage 85 140 210 260 320 380 380 V Current 28 28 28 28 28 28 25 A cos 0 82 0 72 0 76 0 71 0 69 0 75 0 75 Note on operation with static frequency conv...

Страница 16: ...16 Arms p0322 Maximum speed 42 000 rpm p0326 Stalling torque correction factor 100 p0335 Cooling type Liquid cooled p0341 Moment of inertia 0 0013153 kgm p0348 Field weakening operating speed VDC 600...

Страница 17: ...Stator Stator U DFP Digitale Feldplatte Differential magneto resistor 0 75 mm 0 14 mm 0 14 mm U V W PIN 3 7 4 pole 4 7 2 pole 2 7 2 pole 2 4 2 pole 3 7 2 pole AC 7 01 2 PTC PTC AC 8 01 4 C B A G blau...

Страница 18: ...cording to the positive temperature coefficient thermistor temperature TPTC small signal resistance Technical Specifications Type M135 Max operating voltage TA 0 40 C V max 30 V Max measuring voltage...

Страница 19: ...ital differential magneto resistor S signal Note Resistor Rx If the resistor Rx is already integrated in the evaluation unit FC u Only connect signal and ground Supply voltage U Rx Signal 8 V 220 1000...

Страница 20: ...G Risk of injury due to flying parts The HF spindle operates at high speeds which may cause chips to fly out with great force u Never remove the protective devices of the machine or system u Always we...

Страница 21: ...e and free of strain Seal all connections for compressed air axially in relation to the tightening direction Seal all connections for cooling water axially in relation to the tightening direction If t...

Страница 22: ...s immediate corrosion on bare parts which is often unno ticeable at first but later leads to serious corrosion damage Do not use pure or distilled water Deposits in cooling channels due to unsuitable...

Страница 23: ...n air quality see Air purity classes ISO 8573 1 23 section The adjustment value for the sealing air depends on the hose diameter and length Hose diameter DN 4 The setting value can be found in the fol...

Страница 24: ...the centrifugal forces q The clamping system is shifted q The balance of the HF spindle is affected q The bearing is damaged Turn the shaft of the spindle at least ten times by hand Before storing an...

Страница 25: ...rding this to the machine controller for evaluation 9 4 Commissioning after storage Do not put the HF spindle into operation until its temperature has adjusted from the temperature of the storage loca...

Страница 26: ...F spindle is affected q The bearing is damaged 10 1 Clockwise and counter clockwise Sample illustration Direction of rotation indication The HF spindle clamping system is designed for clockwise and co...

Страница 27: ...service set Insert the tool taper into the HF spindle See figure Joining position Insert the hexagon wrench into the threaded spindle through the access hole Tighten the threaded spindle clockwise wit...

Страница 28: ...ments may be flung out u Note the maximum speed for the selected tool u Note the maximum speed for the HF spindle u The maximum permissible speed of the HF spindle for commissioning processing is alwa...

Страница 29: ...to the openings of the HF spindle 12 2 Daily cleaning To ensure that the HF spindle functions safely and accurately all contact sur faces of the HF spindle the mount for the HF spindle the tool mount...

Страница 30: ...zontal position Store the HF spindle so that it is protected from moisture dust and other environmental influences Note the following storage conditions Temperature of storage location 10 C 45 C Relat...

Страница 31: ...n More than 90 of the materials used in the HF spindle can be recycled alu minum stainless steel steel copper etc The HF spindle may not be disposed of with normal domestic waste Remove all non recycl...

Страница 32: ...energy supply companies u Before commencing work switch off the power supply of the HF spindle Note Damage due to electrostatic discharge Do not touch the electrostatic sensitive components of the HF...

Страница 33: ...er See also Spindle becomes hot 33 Frequency converter has shut down q Check the error messages in the frequency converter man ual HF spindle becomes hot Cause Troubleshooting Insufficient cooling q C...

Страница 34: ...HF spindle vibrates oscillates Cause Troubleshooting Tool unsuitable q Only use balanced tools Also see the Tools for high speed cutting 28 section q Check whether the tool is suitable for the applica...

Страница 35: ...1 5 6 1 5 8 1 5 9 1 6 4 1 6 5 1 7 1 1 7 1 1 1 7 2 1 7 3 1 7 4 The incomplete machinery in its standard design complies furthermore with the following applicable regulations Applicable harmonized stan...

Страница 36: ...rlen GERMANY 49 0 6002 9123 0 sales anakanishi jaeger com www nakanishi jaeger com Serial number Type Z100 M536 03 S5 Item no 10205020 Revision 05 Date 01 09 2023 Language EN Jaeger Spindles North Ame...

Отзывы: