5. GENERAL INFORMATION

DANGER!

The unit is not intended for industrial applications.
Do not insert objects into the supply and return air openings.
 

 IMPORTANT!

– 

  the unit will only function correctly if the installation and operation manual is strictly followed.
– 

  all clearances indicated in the manual must be respected in order to guarantee performance, and to 

allow installation and maintenance.

– 

  in case valve packages are to be installed, make sure that there is enough room left.
– 

  periodic access to the unit is required for inspection, maintenance and repairs.
– 

  pay attention to the signs and symbols indicated on the fan coil units.

Unit identification:

The serial number is tagged on unit’s right side (on the left if the connections are on the unit’s right 
side).

Information regarding unintended use:

The unit has been designed to function as a fan coil for both heating and cooling applications; any 
other use is strictly forbidden. Installing the unit in an explosive environment is prohibited.

Decommissioning:

When the unit is not used for long periods of time, it must be disconnected from the mains electrical 
connection.
If the unit is not used during the winter period, the water in the system may freeze. A suitable quantity 
of anti-freeze liquid should be mixed with the water.

Mixing the water with glycol modifies the unit’s performance. Pay attention to the safety 

instructions on the packaging regarding glycol.

Restart after prolonged shutdown:

Before restarting:
– 

  clean or replace the stainless steel fan guard.
– 

  clean the coil.
– 

  clean or unclog the condensate drain.
– 

  bleed the air from the hydronic system.
– 

  it is advisable to run the unit at maximum speed and to check for abnormalities.

5.1. OPERATIONAL LIMITS:

An installation that does not meet the specified operational limits releases Jaga NV from all liability 
with respect to damage to objects or people.
– 

  mains voltage: 120V - 1 ph - 60Hz
– 

  maximum water inlet temperature: 90°C - 194°F
– 

  maximum exchanger pressure: 20 bar - 290PSI
– 

  supply voltage: 120V ±10 %

EN 

   5

JAGA CANADA   |   BRIZA 26  |   MANUEL   |  2022.09.27   |   V.01

Содержание BRIZA 26

Страница 1: ...BRIZA 26 MANUAL...

Страница 2: ...IT 20 11 WARRANTY 20 12 DISSASSEMBLY INSTRUCTIONS 20 13 REFERENCE STANDARDS 21 DECLARATION OF CONFORMITY JAGA N V Verbindingslaan 16 B 3590 declares under its sole responsibility that the product to w...

Страница 3: ...tenance has been carried out by unauthorized people maintenance has been carried out by someone other thanJaga access to the unit has been restricted due to on site conditions the initial start up has...

Страница 4: ...the packaging within reach of children 4 INSTALLATION installation must be carried out by certified technicians Incorrect installation could cause product failure a reduced performance or an increase...

Страница 5: ...dden Installing the unit in an explosive environment is prohibited Decommissioning When the unit is not used for long periods of time it must be disconnected from the mains electrical connection If th...

Страница 6: ...tion for the maximum current required Make sure the electrical supply system complies with current National safety regulations The connections must be implemented in accordance with the diagrams suppl...

Страница 7: ...mum permitted water temperature must be taken into account in function of the relative humidity and temperature of the ambient air 5 3 1 PERMITTED MINIMUM WATER TEMPERATURE C AMBIENT TEMPERATURE DRY B...

Страница 8: ...t spiggot 2 cm Replaceable polypropylene dust filter class G2 Electrical connection Centrifugal fan s with double inlet 6 2 CONFIGURATION BABW BT BABW BF BABW FT BABW FF SUCTION the bottom of the unit...

Страница 9: ...GHT 22 22 22 WIDTH 10 10 10 LENGTH 52 63 77 A 62 74 88 B 60 71 85 6 3 DIMENSIONS L 22 13 3 10 L 2 A B B 11 B 2 B A 3 11 2 3 L 11 25 1 15 13 5 Min 3 1 3 1 Dimensions in Inches EN 9 JAGA CANADA BRIZA 26...

Страница 10: ...6 3 1 Installation dimensions L 5 7 9 7 5 5 5 5 9 5 10 12 12 10 7 5 6 6 Dimensions in Inches 10 JAGA CANADA BRIZA 26 MANUEL 2022 09 27 V 01...

Страница 11: ...sions in Inches 7 INSTALLATION With casing Mark and drill the mounting holes for the back plate and the device 1 8 Without casing Mark and drill the mounting holes for the the device The type of wall...

Страница 12: ...CASING 1 Place the screws of the device 5 8 and let them stick out 1 cm 1 2 Place the device in the correct position 3 Tighten the screws 2 1 2 Connect the device electrically 04 120V 60Hz 0 10V Spee...

Страница 13: ...sation water is drained quickly 3cm m The condensate drain system must be set up with an adequate p trap in order to prevent the infiltration of odours Always install a plug for cleaning in the lower...

Страница 14: ...rews in the mounting holes Ideally the air is blown towards the wall Mount the casing Make sure the mounting holes are in line with the support bolts 1 Secure the casing by tightening the stay bolts 2...

Страница 15: ...f the unit the top of the unit Dynamic Low H2 O hydrophilic coil Hydraulic connection 2 pipe 3 4 G Condensate pump Hydraulic connection 4 pipe 1 2 G Condensate tray with outlet spiggot 2 cm Replaceabl...

Страница 16: ...HEIGHT 22 22 22 WIDTH 10 10 10 LENGTH 49 59 74 22 11 10 L 3 L 1 L 13 1 Dimensions in Inches 8 3 1 Installation dimensions max 118 max 118 12 12 5 5 6 6 5 5 Dimensions in Inches 16 JAGA CANADA BRIZA 2...

Страница 17: ...that the wall is level and has sufficient loadbearing capacity 01 02 1 Place the screws of the device 5 8 and let them stick out 1 cm Use a washer between screw head and the appliance 1 2 Place the d...

Страница 18: ...the hydraulic pipes must be insulated When using devices for cooling iron couplings prohibited 03 Use a back off wrench when faste ning the hydronic connections Remove black plug at hydraulic connecti...

Страница 19: ...witch to isolate the unit from the mains before carrying out any maintenance or inspection work Make sure that no one accidentally turns on the power to the unit lock the master switch in the off posi...

Страница 20: ...y cleaned the unit has been used in an improper or irresponsible manner repairs have been carried out by others than Jaga product modifications have been carried out by others before or after the inst...

Страница 21: ...ssential to the brazing process test conditions assessment and certificates EN 378 1 Refrigerating systems and heat pumps Safety and environmental requirements PREN 378 2 Refrigerating systems and hea...

Страница 22: ...27200 20000056 2022 09 27 Jaga Inc Jaga Canada Climate Systems www jaga canada com...

Отзывы: