background image

 

OPERATION AND MAINTENANCE MANUAL 

12-2015

 

 

 

TYPE 8010 
 
 

DN

RD

H*

H

1

H

2

Weight

[inch]

[kg]

1000

1930

35

1250

2180

39

1600

2430

43

1800

2730

47

3/4"

885

600

[mm]

 

 

Detail "A" 

Detail "B" 

Содержание 8010

Страница 1: ...President of Factory JAFAR S A Failure to comply with the guidelines and instructions in this Operation and Maintenance Manual releases the manufacturer from all obligations liability and guarantee Du...

Страница 2: ...RIPTION 3 2 2 MATERIALS 4 2 3 DIMENSIONS 5 2 4 STANDARDS 7 2 5 ORDERING REGULATIONS 7 2 6 MANUFACTURE AND ACCEPTANCE 8 2 7 MARKINGS 8 3 PROTECTION STORAGE TRANSPORT 8 3 1 PROTECTIVE COATINGS 8 3 2 PAC...

Страница 3: ...hydrant s foot is placed on the ground above water supply network s pipe The valve chamber contains a closing component a poppet valve connected to the outlet in the upper part of the hydrant using a...

Страница 4: ...Material Reference standard 1 Body Cast iron EN GJS 400 15 PN EN1563 2012 2 Bonnet Cast iron EN GJS 400 15 PN EN1563 2012 3 Dome Cast iron EN GJS 400 15 PN EN1563 2012 4 Decorative ring Cast iron EN G...

Страница 5: ...OPERATION AND MAINTENANCE MANUAL 12 2015 5 2 3 DIMENSIONS TYPE 8001 DN mm 3 4 1000 1250 1500 RD 1800 2000 2250 2500 L 2800 Detail A Detail B...

Страница 6: ...OPERATION AND MAINTENANCE MANUAL 12 2015 6 TYPE 8010 DN RD H H1 H2 Weight inch kg 1000 1930 35 1250 2180 39 1600 2430 43 1800 2730 47 3 4 885 600 mm Detail A Detail B...

Страница 7: ...2001 ISO general purpose metric screw threads Tolerances Principles and basic data PN ISO 2903 1996 Trapezoid ISO metric threads Tolerances PN EN ISO 4762 2006 Hexagon socket headcap screws PN EN ISO...

Страница 8: ...ures the nameplate which contains the following data manufacturer s company name and logo product serial number sealing temperature grade the Polish Building Mark B and or the CE mark as applicable pr...

Страница 9: ...OPERATION AND MAINTENANCE MANUAL 12 2015 9 3 4 TRANSPORT Transport the hydrants using sheltered vehicles...

Страница 10: ...ons A hydrant assembled and adjusted by the manufacturer is ready for installation in the system Any dismantling of the hydrant components may result in loss of tightness 4 2 INSTALLATION INSTRUCTIONS...

Страница 11: ...e regulations defining the need for water for social uses The diagram above shows the installation method for standpost hydrant the installation method largely depends on the applied rules based on lo...

Страница 12: ...ecommendations for installation of water systems and devices installed in water supply stations and other facilities apply Misuse of this product is prohibited 5 GUARANTEE CONDITIONS The manufacturer...

Отзывы: