4.2 ASSEMBLY INSTRUCTIONS 

 
 

Before attempting to install the valve, check the technical and commercial documents delivered with the 

product  to  verify  that  the  media  and  pipeline  operating  parameters comply with the manufacturer's declaration. 
Any change in the operating conditions must be consulted with the valve manufacturer beforehand. 
 

Before  attempting  to  assemble  the  valve,  remove  the  main  bore  plugs,  check  the  inner  surfaces  of  the 

valve and thoroughly flush with water, if necessary. 
CAUTION! If the product is damaged mechanically, do not install it in the pipeline. 
 

 

The figure below shows the method for coupling the gate valve and the valve orientation diagrams: 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
1. Valve; 2. Nut; 3. Gasket; 4. Pipeline flange; 5. Washer; 6. Fastening bolt 
 

4.3 OPERATION 

 

The gate valve shall be operated according to all relevant requirements for cut-off valves, i.e. either in fully 

open or fully closed positions. Leaving the gate valve partially opened (or closed) may result in seal failure. To 
ensure full performance, switch the knife gate valve periodically (once a year, from fully open to fully closed). 
Exceeding the operating limits of the valve may result in damage that will not covered by the suretyship granted 
by the manufacturer. 

 
4.4 OCCUPATIONAL HEALTH AND SAFETY 

 
 

The valves are eligible for the OHS guidelines and recommendation concerning installation of pipelines 

and  devices  for  water  supply  stations,  heat  power  plants,  water  treatment  plants,  sewage  treatment  plants, 
pumping stations and other facilities, and eligible for the Polish Regulation concerning general OHS laws (use of 
personal protective equipment for hands, legs and head, and safety garment), especially at work with low or high 
temperature hazard. 
Misuse of this product is prohibited. 
 

5 WARRANTY TERMS AND CONDITIONS 

 
 

The  product  assembled,  installed  and  operated  in  compliance  with  this  Manual  is  covered  by  a 

commercial  warranty  from  the  manufacturer.  The  conditions  and  period  of  the  warranty  is  specified  in  the 
warranty sheet. 

Recommended 

Not permitted 

Permitted 

Содержание 2502

Страница 1: ...ved for use by President of Factory JAFAR S A Failure to comply with the guidelines and instructions in this Operation and Maintenance Manual releases the manufacturer from all obligations liability a...

Страница 2: ...3 2 2 MATERIALS 4 2 3 DIMENSIONS 5 2 4 REFERENCE STANDARDS 6 2 5 ORDERING INFORMATION 6 2 6 PRODUCTION AND ACCEPTANCE 6 2 7 MARKINGS 7 3 PROTECTION STORAGE TRANSPORT 7 3 1 PROTECTIVE COATINGS 7 3 2 PA...

Страница 3: ...Nm 55 80 100 200 Valve control mode the standard version of gate valve has the clockwise closing sense of rotation The closing sense of rotation can be opposite on special order Installation length E...

Страница 4: ...2 Cover Cast iron EN GJS 400 15 EN GJS 500 7 EN 1563 3 Wedge Cast iron EN GJS 400 15 EN GJS 500 7 Rubber EPDM NBR EN 1563 EN 1629 4 Skid Polyamide EN ISO 1874 1 5 Spindle Steel grade 1 4057 1 4021 EN...

Страница 5: ...18 19 80 180 280 385 132 200 160 19 19 3 8 200 17 21 23 100 190 300 435 156 220 180 19 19 3 8 250 19 30 33 125 200 325 475 184 250 210 19 19 3 8 250 19 36 42 150 210 350 535 211 285 240 23 19 3 8 250...

Страница 6: ...ular nuts style 1 Product grades A and B ISO 965 1 General purpose ISO metric threads Tolerances Principles and basic data ISO 2903 Trapezoid ISO metric threads Tolerances EN ISO 4762 Hexagon socket h...

Страница 7: ...following data manufacturer s company name and logo serial number sealing temperature rating construction mark B and or mark CE as applicable product type 3 PROTECTION STORAGE TRANSPORT 3 1 PROTECTIVE...

Страница 8: ...d in surface pipelines both in horizontal or vertical orientation The listed products are suitable for joining with the flanged ends of pipelines with the size equal to that of the valve flanges Note...

Страница 9: ...ions Leaving the gate valve partially opened or closed may result in seal failure To ensure full performance switch the knife gate valve periodically once a year from fully open to fully closed Exceed...

Отзывы: