3
Remove Handle and Trim from Valve. See step 1 for reference.
Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve, if present.
TO GAIN ACCESS TO VALVE FOR SERVICING
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6). Remove
CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see
above for installing TRIM and HANDLE.
VALVE LEAKS WHEN SHUT OFF
BACK TO BACK INSTALLATION
ROTATE 180
˚
Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth. Order Repair
Part M952100-0070 if balancing unit is defective.
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top flange should butt-up against top of casting.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
1
2
9
5
5
7
8
6
4
3
INLETS
LARGE OUTLET
1 0 9 4 9 3 A
1/2" NPT
FINISHED WALL
BOTTOM OF
TUB
OR SHOWER
STALL
48" TO 54"
OPTIONAL
OPTIONAL TO
FINISHED FLOOR
USUALLY BETWEEN
72'' AND 84"
"SEE ILLUSTRATION"
1-5/8" TO 3-1/4"
For reference
ROUGHING-IN DIMENSIONS
7-7/8"
SHW
TUB
THREADED INLETS (STOPS)
OUTLETS 1/2" NPT
INLETS 1/2" NPT
5-7/8"
3-3/8"
1/2" PLUG
Plumbers' Putty or Caulking
Adjustable Wrench
Teflon Tape
Phillips Screwdriver
Channel Locks
TOOLS REQUIRED
Tubing Cutter
Regular Screwdriver
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the
HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
1
51
31
19
75
31
0
1
5
1
3
1
1
9
7
5
3
1
1
5
1
3
1
1
9
7
5
3
1
2
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
Remove Handle Assembly and Trim. See above step 1 for reference.
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to HOT
LIMIT STOP (1). Use a flat blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1). Pull
forward and rotate counterclockwise one number to limit hot water temperature.
Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1)
for indication.
1
5
1
5
4
4
3
3
2
2
ADJUST HOT LIMIT STOP (MUST BE DONE PRIOR TO TRIM INSTALLATION)
1 0 9 4 9 3 A
Turn off water at main supply.
CAUTION
INSTALL TRIM
INSTALL HANDLE (ADJUST HOT LIMIT STOP
PRIOR TO HANDLE INSTALLATION,
SEE STEP 3)
Lever Handles:
Thread HANDLE BASE (4) onto
threads of CAP (1) until seated against it's internal
stop. Install FRICTION WASHER (14) onto base
of LEVER HANDLE (12). Align LEVER HANDLE (12)
and tighten set screw with HEX WRENCH (13)
supplied with faucet to secure handle.
For Cross Handle:
Thread HANDLE BASE (8) onto
threads of CAP (1) until seated against it's internal
stop. With VALVE in off position align CROSS
HANDLE (9) as desired. Install CROSS HANDLE (9)
onto VALVE STEM (15) and tighten HANDLE
SCREW (10). Thread INDEX (11) into
CROSS HANDLE (9).
CROSS HANDLE
LEVER HANDLES
8
10
9
11
4
12
13
14
THREADS
ON CAP
1
15
7
3
5
6
Push CAP (1) onto VALVE CARTRIDGE (2). Secure CAP (1) to
VALVE CARTRIDGE (2) with SCREW (3) for LEVER HANDLE only.
(Spline in CAP (1) must fully engage spline on cartridge stem).
Push the COVER (7) as shown over the CAP (1) and align
prongs on COVER (7) with screw holes in ESCUTCHEON (5).
Important! Make sure COVER (7) snaps over the SCREWS (6).
1
1a
Mount ESCUTCHEON (5) with gasket to valve body and secure
with SCREWS (6).
2