JADEVER SCALE CO.,LTD

 

 

                                                    NWTE WEIGHING SCALE                                                                  PAGE 

3

 

Simple Counting 

1.  Press        to select the unit “PCS”. 

2. Press 

  to choose the sampling amount .Available options are  =

(10 pieces), 

=

(2 pieces),  =

(50 pieces), and  =

(100 pieces). 

3. Put 

the 

corresponding samples on the weighing pan, then press          .. 

 “

” is displayed momentarily before the display reverts to the sample size. Remove the 

samples and put the load on, the scale begins to count. 

NOTE

 : 

 

◎ 

The larger the sample size, the more accurate unit weight. 

◎ 

The sampling result is retained when the unit is turned on. 

Setting mode 

1.  Press and hold

 

  while turning on the scale. Do not release 

  till the OFFSET 

value is displayed.   

2. Press 

, the screen displays “

” 

3. Press 

  to step through available settings   

4. Press 

  to initial the displayed setting , then press 

  to step through internal 

parameters . 

5. Press 

  to save the setting ,    press 

  to exit without saving. 

6. Press key 

 

to save the settings and back to the weighing mode. 

Description of Parameter Values 

Set the brightness of the LED display. The higher the setting, the brighter.     

Options are 1,2,3 and 4(level) 

  Set the period of inactivity before the scale automatically turns off. Options are 

NO=non power-off, 5,10 and 15( minutes). 

 

       

                 

 

Содержание NWTE

Страница 1: ...ut off for power saving Powered by 4 C size batteries or AC adapter Precaution 1 Place the scale on a flat and stable surface and install the weighing pan properly 2 Do not operate the scale in hostile environments 3 Avoid sudden temperature changes suitable operating temperature is between 5 40 4 Do not drop loads on the platform 5 Do not immerse the scale in water or other liquids ...

Страница 2: ...tteries are properly orientated The negative battery terminals should face the spring contacts 2 Connecting AC power Plug the AC adapter into the adapter jack and connect to a convenient power outlet Keypad and display Turns the scale ON OFF Sets display to zero Tares weight of item on pan Steps through active units Toggles between net gross weight Low battery indicator TARE Tare lamp turns on ind...

Страница 3: ... is retained when the unit is turned on Setting mode 1 Press and hold while turning on the scale Do not release till the OFFSET value is displayed 2 Press the screen displays 3 Press to step through available settings 4 Press to initial the displayed setting then press to step through internal parameters 5 Press to save the setting press to exit without saving 6 Press key to save the settings and ...

Страница 4: ...isplayed on the screen now remove the weights 6 Press to return to normal weighing mode Troubleshooting and error message Error Message Trouble shooting 1 Confirm that there is nothing on the weighing platform and reboot the scale 2 LOAD CELL failure please contact our Service 1 PCB or Load cell is defective please contact our Service Reboot the scale 1 Confirm that there is nothing on the weighin...

Отзывы: