![Jadever JWI-700W Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/jadever/jwi-700w/jwi-700w_manual_630840009.webp)
J ADEVER SCALE CO., LTD
JWI-700W 8
4) P03
Set RS-232 Serial Transmission Rate.
Options are bA-96(9600), BA48(4800) and
BA24(2400).
5) P04
Set check weighing memory.
= Previously set checkweighing values are not retained when the unit is turned on.
= Previously set checkweighing values are retained when the unit is turned on.
6) P05 Enable or disable RTC function.
= enable RTC function
= disable RTC function
7) P06 Set the activation mode of backlight. Options are ONOFF (Auto on with items greater
than 9d placed on the weighing pan or any key is pressed), ON (Backlight on) and OFF (No
backlight)
8) P07 Set Print mode.
= manual print
= Stable print
= Continuous print
9) P08 Set the filtering level in which the stable indication turns on .The higher the setting, the
slower stabilization time. Options are Fil 1,Fil 2,Fil 3 and Fil 4.
10) P09 Set the range in which the Zero indication turns on . Options are Zero.0(1 division) ,
Zero.1(2 divisions), Zero.2(3 divisions), Zero.3(4 divisions ), Zero.4(5divisions) and
Zero.5(6divisions ) .
11) P10 Initial Setup (not available)
12)P11 Unit setting (refer to section 7-3).
13) P12 Set the peak value display period (refer to section 7-7)
14
)
P13 In the peak hold & weighing mode, select to display value of peak weighing or value
of stable weighing.
= display
value of peak weighing
= display
value of stable weighing.
6. Calibration mode
6-1 Single point calibration
1
)
Press and hold key
M-
while powering on the scale. The screen displays “ ”, then
release the keys.
2
)
Press key
TARE
to enter the zero point calibration mode, with “ ” appears then
flashes.
(
Please put no load on the weighing pan at the moment.
)