IDS701-CTRUCK User Manual
Page 18 of 21
6. Maintenance
6.1
Regular Error and maintain method
Error
Reason instruction
Solution
Display
UUUUUU
1. the loaded weight
excess overload
range of max. capacity
2. wrong connection
with load cell or no
connection with it.
3. load cell
unworkable
1.decrease loaded weight
2. check load cell
connection
3. checking load cell
:
check input and output
resistance to judge it is
good or not.
Display nnnnnn
1. calibration is no
good
2
、
cell single line is
connect a wrong line.
3
、
the cell is bad.
1. check scale is resisted
or not, foot is kept level
or not.
2. check load cell
connection.
3. checking load cell
:
check input and output
resistance to judge it is
good or not.
ERR1
during calibration, no
input added weight or
input weight exceed
max capacity.
Input the correct weight