INST 448 Jacuzzi® JVX Series Pool pump V10-17 

GENERAL 

The Jacuzzi® JVX Series Pool Pumps have a unique variable-speed AC motor combined with an energy efficient 
pump wet end.   When installed and plumbed correctly, the Jacuzzi® JVX Series Pool Pump will significantly 
reduce operating costs, lower noise levels and reduce greenhouse emissions. 
 

When you receive the pump, check the carton for damage. Open the carton and check the pump for concealed damage, 
such as cracks, dents, or a bent base. If you find damage, contact the shipper or the distributor where the pump was 
purchased. 
The pump must be placed on a solid foundation that will not vibrate, Jacuzzi® recommends bolting the pump to the 
foundation and providing adequate drainage should any leaks develop. 

 

The Jacuzzi® JVX Series Pool Pump range is available in a variety of models, with the following factory set speeds 
which offer approximate flow rates: 
 
 

Model 

Voltage 

High 

Medium 

Low 

Jacuzzi® 

JVX160 

220 VAC 

 
 

110 VAC 

72 gpm 

3075 RPM 

 

64 gpm 

2850 RPM 

49 gpm 

2000 RPM 

 

49 gpm 

2000 RPM 

40 gpm 

1325 RPM 

 

40 gpm 

1325 RPM 

Jacuzzi® 

JVX300 

220 VAC 

 
 

110 VAC 

82 gpm 

3400 RPM 

 

68 GPM 

2850 RPM 

54 gpm 

2000 RPM 

 

54 gpm 

2000 RPM 

38 gpm 

1150 RPM 

 

38 gpm 

1150 RPM 

(Flow rates based on a maximum speed at 26 feet total dynamic head). 

 
Each speed can be easily changed to suit your pool size, filter, plumbing and application.  The Jacuzzi® JVX Series 
Pool pump must be installed by a pool professional trained by Jacuzzi® to ensure it has been selected for the 
correct application, correctly installed and set up to suit your pool and its operation fully explained to you

FEATURES 

 

-

 

Continuous duty rated motor 

-

 

Timers and pump speed can be controlled using Bluetooth from compatible phones, tablets etc (JVX300 
only) 

-

 

Precision reinforced moulded high head impeller, giving extra performance 

-

 

Single piece moulded body for added strength and longer life 

-

 

Rapid priming diffuser quickly corrects loss of water flow 

-

 

Quick and easy disassembly for servicing 

-

 

Large capacity basket with easily removed ramp on lid 

-

 

Ability to adjust factory pre-set speeds for optimum water flow and maximum energy savings for your 
pool and its equipment. 
 

  

WARNING

 

Jacuzzi® JVX Series Pool pumps include PCB’s and microchips. It is necessary to turn power off completely for 10 
seconds before turning pump back on again. Some brands of chlorinators may bleed a small amount of power into the 
Jacuzzi® JVX Series Pool pump even when the pump off mode is selected. If this occurs, the Jacuzzi® JVX Series Pool 
pump may not reset correctly and may not start until power is disconnected completely. In some cases, the manufacturer 
of these chlorinators may be able to remove or change a capacitor in the chlorinator which will completely disconnect 
power to the pump when turned off. If not, a suitable chlorinator may be required to be purchased. Jacuzzi® J-SS40 
chlorinators completely disconnect power to the pump when the pump off mode is selected. 

 

 

 

Содержание JVX300

Страница 1: ...Jacuzzi JVX160 JVX300 Pump Installation and Operating Instructions ...

Страница 2: ...by a ground fault circuit interrupter GFCI Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be restored If the GFCI fails to operate in this manner the GFCI is defective If the GFCI interrupts power without the test button being pushed a ground current is ...

Страница 3: ...eries Pool pump must be installed by a pool professional trained by Jacuzzi to ensure it has been selected for the correct application correctly installed and set up to suit your pool and its operation fully explained to you FEATURES Continuous duty rated motor Timers and pump speed can be controlled using Bluetooth from compatible phones tablets etc JVX300 only Precision reinforced moulded high h...

Страница 4: ...connections are clean and tight 3 Cut wires to the appropriate length so they don t overlap or touch when connected to the terminal board and insulate all connections carefully to prevent grounding or short circuits 4 Permanently ground the motor using the green ground terminal located on the inside of the motor canopy under the access plate 5 Use the correct wire size and type specified by the Na...

Страница 5: ...e gloves when handling and using glue and priming fluid Ensure no excess adhesive runs into the union proper affecting the sealing or removal abilities Do not drip glue on the pump body as it will mark it Allow 24 hours to dry before starting pump D Install isolation valves before the pump section and after equipment if the pump is below the water level of the pool E For pump installations 19 abov...

Страница 6: ... 125 or a 10 75 inch pump inlet centerline to ground clearance which allows easy retrofits from popular competitor pump products 3 Align pump foot over mating features on the adjustable base after selecting correct base side from step 2 which allows for closely matching existing pump installations inlet centerline 4 Apply moderate down pressure to pump foot to clip pump into base clips locking it ...

Страница 7: ...g circles The pump will then prime 30 faster than at the conventional maximum speed During this priming period the pump will automatically limit its maximum speed according to the systems total dynamic head and power consumption Once the pump has primed or if it fails to prime within 5 minutes the speed will drop to the speed that it last ran in Manual mode 5 If some flow of water does not establi...

Страница 8: ...physical sensory or mental capabilities or lack of experience or knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Please ensure that young children are supervised to ensure that they do not play with the pump Control using Bluetooth Compatible Phones JVX300 pumps can be controlled from a Bluetooth compatible p...

Страница 9: ...ure that a you have adequate chlorine and b the water in your pool looks clear and inviting If you have any doubts take a sample of water to your local pool shop for a water analysis Examples of Speed Selection during operation and use of your Jacuzzi JVX150 and JVX250 Pool Pumps Function Speed Vacuuming Pool or Spa High Speed Operating Spa Jets High Speed Operating Waterfall or Water Feature Medi...

Страница 10: ...eriods can be disused and 1 2 3 or 4 periods selected Different speed low medium high for each timer period Displays actual RPM of motor and low medium and high speed can be adjusted to suit your pool Time clock and timer periods can be disabled if connected to an external time clock Enables the priming start up speed to be adjustable and the time of the start up speed to be changed from 2 minutes...

Страница 11: ...een High is represented by speed 1 medium by speed 2 and Low by speed 3 6 Press Enter to move to the stop or end time of Timer 1 Use the up and down arrows to change the end of Timer 1 7 Timer 2 will now appear on the LCD Screen Repeat instructions 4 to 6 Above 8 Timer 3 will now appear but is factory pre set to OFF Moving any timer to midnight will turn that Timer period off Use the up and down a...

Страница 12: ... Priming period From 2 minutes up to 120 minutes Press ENTER to accept Screen will Flash 5 Press Auto to exit the programming Fault Codes The Jacuzzi JVX160 and JVX300 Pool Pump Fault Code displayed on screen Meaning HI T Over Temperature HI A Over Current Lo V Under Input Voltage BSUC Motor is Stuck Please note It is normal for the Lo V fault code to display briefly on start up Pump will retain a...

Страница 13: ...nd lint pot chamber To operate a suction cleaner on your pump 1 Choose the speed button low medium or high on which the pump will operate when the suction cleaner is connected 2 Allow pump to operate for a minimum of 2 minutes to allow a full prime to be achieved 3 Connect cleaner plate and hose to skimmer wall suction only after all air has been purged from the top of the hair and lint pot of you...

Страница 14: ...iner pot if the pump fails to prime or if the pump has been operating without water in the strainer pot Pumps operated in these circumstances may experience a buildup of vapour pressure and may contain scalding hot water Opening the pump may cause serious personal injury In order to avoid the possibility of personal injury make sure the suction and discharge valves are open and the strainer pot te...

Страница 15: ...s ventilation 2 Protect the motor from excess dirt and debris Protect it from splashing water and foreign matter Do not store or spill pool chemicals near the motor Avoid sweeping or stirring up dust near the motor while it is operating if the motor is damage by dirt it voids the motor warranty 3 Protect the motor from excess moisture splashing pool water lawn sprinklers rain If the motor has beco...

Страница 16: ...nt ant and insect ingress Every 3 Months Check for leaks from underneath pump Call Service technician repair or replace mechanical seal and motor bearings if necessary Important note Regular maintenance is important to ensure long life and trouble free performance of your pool equipment If unable to perform the maintenance yourself contact www Jacuzzipool com who will arrange a trained service tec...