16.2 North American 1-Pump Convertible Models
This wiring diagram is used for all 1-Pump 120/240V 60 Hz North
American convertible spa models.
CLEAR
RAY
Stereo power Supply (optional)
Pump 1 2 speed
1
2
3
4
OZONE
PUMP 1
UV
A/V
30A
5AT~250V
30A
120VAC, 12A 3-WIRE CONNECTION
240VAC, 20A/31A 4-WIRE CONNECTION
WHT
BLK
G-GRN
STEP LIGHT
(OPTIONAL)
Water Sensor
Flow sensor
WHT
BLK
Control panel
Light Adapter
1.0kW/4.0kW HEATER
THERMAL CUTOFF
S1
ON
1 2 3 4 5 6 7 8 9 10
Bridge (optional)
DANGER
Turn power off before servicing. This task should only be performed by a quali
-
fied technician.
!
RISK OF SHOCK OR ELECTROCUTION!