Section 4b
–SERVICE and MAINTENANCE
Cell
The Cell is installed with Unions on each end of the cell to allow quick and easy removal. Loosen the unions and remove the
cell from the plumbing.
JC13
Side View of Cell and Unions
VISUAL CELL INSPECTION:
The titanium Cell blades, seen inside the Cell body, should be straight and clear of any debris between the blades. Your
Commander III Model JC13 is designed to automatically self-clean scale build-up within the Cell. However, imbalanced water
chemistry and certain conditions can cause a heavier scale build up that exceeds the self-cleaning capability and would need to
be cleaned manually by the method described below.
13
Periodically inspect both ends of the cell.
A White Flaky or Crusty build-up on the
edge or between the blades will prematurely
deplete the life of the cell. Immediately
End View of cell
clean the cell and determine the cause of
Looking at the Titanium Blades
scaling. See Troubleshooting Section, page 14.
MANUAL CELL CLEANING:
With the Cell removed as described above, use a high-pressure hose nozzle to spray off as much loose, soft scale and debris as
possible. Any remaining calcium scale can be treated with a mixture of one (1) part Muriatic Acid into four (4) parts water.
Mix the solution in a container high enough to cover the Cell blades. You may also use
TABEX LectraClean™ (
non-
fuming/pre-mixed) cell cleaner, per label directions.
Remove the Cell cord and immerse the Cell so that the blades are completely covered in the solution for up to 15 minutes. An
effervescences action indicates the calcium is being neutralized and cleaned. Drain the cell, flush with fresh water and re-
inspect. Repeat the immersion if necessary. Once the cell has been cleaned and rinsed; it may be re-installed in-line. BE
SURE THAT THE CELL “PINS” ARE CLEAN AND DRY BEFORE ATTACHING THE DC CORD FROM THE POWER
SUPPLY.
WARNING: ALWAYS ADD ACID TO WATER, never water to acid.
When replacing the cell, only use replacement cells having a label that clearly states that it is a replacement cell for the chlorine
generating device Commander III Model JC13, REGISTRATION NUMBER 27843.01, PEST CONTROL PRODUCTS ACT.
NEVER USE ANY SHARP OR METALLIC OBJECTS TO REMOVE SCALE. Scraping or scratching the titanium
blade’s edge or surface will allow chemical attack of the blade, cause premature failure of the Cell and will void your
warranty.
Hacksaw Blades
Screwdrivers
Forks
Knives
FILTER BACKWASHING:
NOTE: The Control Panel Output setting must be set to 0% (OFF) when backwashing the filter.