CONFIGURATION 1: Typical End-of-line Cell Installation (With or without
Flow Switch) Install per diagram below.
Ground Mounting Kit
consists of:
(2) 91.5 cm - 1.9cm x 1.9cm x
.3cm (3' - 3/4" x 3/4" x 1/8")
aluminum angles with four
predrilled 0.156 in. holes
(4) #10-32 .9 cm (3/8") S.S.
screws. Two for each side
installed within the back-plate
mounting feet.
OPTIONAL GROUND MOUNTING SUPPORT
STEPS FOR INSTALLATION
STEP 1
Choose an adequate location for your COMMANDER I Unit Control Panel. Read and follow warnings.
Avoid traffic, lawn mowers and sprinklers. Take both 1 m (3 ft) aluminum angle stakes and drive into
ground approximately 31 cm(12”) deep, to the width of the COMMANDER I Unit Control Panel 21 cm (8
1/8”) (Use a 5 cm x 10 cm (2" X 4") block and hammer.)
STEP 2
Slide the COMMANDER I Unit Control Panel over the angle stakes and screw into the predrilled holes.
CAUTION: DO NOT HAMMER THE COMMANDER I UNIT WITH ANY TOOL.
CAUTION: DRIVE STAKES INTO GROUND BEFORE MOUNTING THE COMMANDER I UNIT
CO TROL PANEL.
N
Continued On Next Page
Above Ground Pool Installation Locations
Appendix