Q = q x 600 (L/ha)
v x f
Q = 10 x 600
4 x 4
Q = 6000
16
Q= 375 L/ha
Calculating the spraying volume through formula
• The calibration of sprayers can be ob-
tained through calculations obtained ac-
cording to formula below.
• The spraying volumes can be obtained
according to the following:
Example:
Noozles flow rate = 10 L/min at 150 psi (10 x
JA-2 nozzles)
Row spacing = 4 x 3 m
Working speed = 4,0 km/h
Plants per hectare = 833 plants
Spray calibration
Spray volume per plant:
375 = 0,45 L/planta
833
ATTENTION!
The values indicated on the example above are for illustration purposes. The correct
adjustment should be done according to the recommendations of a trusted technician.
Spraying volume:
Q = q x 600 (L/ha)
v x f
Noozle flow:
q = Q x V x F (L/min)
600
With:
Q - Spray volume (L/ha)
q - Total flow of noozles (L/min)
f - Treated band (meters)
v - Speed of tractor in km/h
600 - Unit conversion factor