background image

August 2015© 

Jacobsen HR9016 ROPS Cab Operator Manual

 

 

 

After your ROPS Cab has been installed: 

 

Before starting a mower equipped with a Tektite ROPS cab: 

 

1. Clear the operator platform  of all tools. Tools left in or around the ROPS  and  mower can 

cause operator interference which could lead to bodily injury and/or damage the machine. 

2. Inspect the ROPS and mower to ensure all bolts are tight and re-tighten if required. 

3. Ensure that all pedals, levers, and controls have adequate clearance for normal operation. 

4. Ensure that all electrical components of both the ROPS and mower operate normally. 

5. Ensure your door latches properly onto the striker pin.  Immediately after installation, the 

ROPS frame may flex slightly from installation, and the door latch will need to be re-aligned for 

proper operation.  Loosen the striker pin, striker mounting plate and door latch as necessary to 

get a proper alignment of the door striker. 

 

 

Service Parts Breakdowns: 

 

Following are parts breakdowns for components that may require service parts replacement 

during the life of the ROPS.  If you require replacement parts, please contact the dealer that 

you purchased the ROPS from and indicate which parts you require. 

 

Содержание HR-9016 Turbo

Страница 1: ...24157 Hwy 3 P O Box 639 Winkler MB R6W 4A8 Canada PH 204 331 3463 Fax 204 331 4159 sales tektite ca One year standard product warranty provided by Tektite Caution Please read installation instructions...

Страница 2: ...may not provide all the detail needed and are for reference only All directions provided are from the reference point of the tractor seat facing the steering wheel All left and right references are f...

Страница 3: ...t if instructions are not carefully followed NOTE All products are designed to give safe dependable service if they are operated and maintained according to instructions It is the owner s responsibili...

Страница 4: ...must be worn at all times when using a ROPS 10 Safety devices and shields are intended to protect operators from injury or death Under no circumstances should they be modified disabled or removed Ope...

Страница 5: ...und use steps and handholds Do not use fenders or shields that are not designed as steps Safe Highway Operation 1 Before operating the mower on or near public roadways check with your local authoritie...

Страница 6: ...damage or involved in an over turn accident the entire structure must be replaced Failure to do so may result in injury or death in the event of a roll over 3 If the mower in not equipped with seat be...

Страница 7: ...operating the mower Failure to do so may result in unsafe operation of the mower and possible injury or death to operators and bystanders There are two switch plates located in the headliner The follo...

Страница 8: ...ates when head lights are on 6 Front and Rear Washer Rocker Switch optional Low position Momentary On Rear Washer Middle position Off High position Momentary On Front Washer 7 Turn Signal Rocker Switc...

Страница 9: ...tivated with this switch lever Cab Circuit Protection The Tektite ROPS cab is wired to provide maximum protection against accidental battery rundown and circuit overload A relay in the cab is ignition...

Страница 10: ...operation 4 Ensure that all electrical components of both the ROPS and mower operate normally 5 Ensure your door latches properly onto the striker pin Immediately after installation the ROPS frame ma...

Страница 11: ...24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0013 TEKT 0009 5MM Bushing 8 2 A00 0019 STEP BOLT1 4X1 Step Bolt 1 4 x 1 MB 4 3 A00 0021 FLANGE NU...

Страница 12: ...nc 24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0013 TEKT 0009 5MM Bushing 8 2 A00 0019 STEP BOLT1 4X1 Step Bolt 1 4 x 1 MB 4 3 A00 0021 FLANGE...

Страница 13: ...andle 1 2 A00 0002 LEFT LATCH Suicide Door Left Latch 1 3 A00 0013 TEKT 0009 5MM Bushing 15 4 A00 0018 STEP BOLT1 4X1 1 2 Step Bolt 1 4 x 1 1 2 MB 3 5 A00 0020 STEP BOLT1 4X1 1 4 Step Bolt 1 4 x 1 1 4...

Страница 14: ...2 A00 0003 RIGHT LATCH Suicide Door Right Latch 1 3 A00 0013 TEKT 0009 5MM Bushing 15 4 A00 0018 STEP BOLT1 4X1 1 2 Step Bolt 1 4 x 1 1 2 MB 3 5 A00 0020 STEP BOLT1 4X1 1 4 Step Bolt 1 4 x 1 1 4 MB 4...

Страница 15: ...s otherwise specified X X 1 16 Angular 1 0 Drawn By Checked By Size File Name Units Date Date Req d Description Tektite Manufacturing Inc 24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Servic...

Страница 16: ...facturing Inc 24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0013 TEKT 0009 5MM Bushing 5 2 A00 0014 TEKT 0092 Thick Bushing 3 3 A00 0019 STEP BOL...

Страница 17: ...ked By Size File Name Units Date Date Req d Description Tektite Manufacturing Inc 24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0095 TEKT 0057 RO...

Страница 18: ...3 A00 0017 305 1002 Panto Mount Plate 1 4 A00 0025 BALL LOUVER 2 1 2 Ball Louver 4 5 A00 0026 OSCILLATING FAN Oscillating Fan 1 6 A00 0038 TEKT 0076 3 Plug 1 7 A00 0055 TEKT 0019 Fir Tree Fastener 2...

Страница 19: ...te Req d Description Tektite Manufacturing Inc 24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 A00 0006 TEKT 0074 Cabin Air Filter 2 2 A00 0070 REID KB...

Страница 20: ...Req d Description Tektite Manufacturing Inc 24157 Hwy 3 Box 639 Winkler MB R6W 4A8 Canada CNC Index Service Part File Name Description Qty 1 JA9016 ASM 22 RADIO 1 2 A00 0021 FLANGE NUT 1 4 Flange Nut...