12 LDU ERROR CODES
en-104
Generator temperature greater than
340° F (171° C). Engine speed is set
to idle.Shut mower down and wait
ten minutes. Restart mower. If fault
returns, return mower to
maintenance shed.
4
4
4
4
4
Generator temperature less than
-20° F (-29° C). Engine speed is set
to idle. Allow engine to run until
generator warms up.
4
4
4
4
4
Rectifier temperature greater than
340° F (171° C). Engine speed is set
to idle.Shut mower down and wait
ten minutes. Restart mower. If fault
returns, return mower to
maintenance shed.
4
4
4
4
4
Rectifier temperature less than -20°
F (-29° C). Engine speed is set to
idle. Allow engine to run until
generator warms up.
4
4
4
4
4
Current sense fault. Current less
than 20A when engine above 2900
rpm. Restart mower. Return to
maintenance shed.