13
Replacement of battery
The mounting plate makes it easy to pull down the smoke alarm for cleaning and
for replacement of the battery . As an extra safety precaution, the smoke alarm
cannot be mounted without a battery . The smoke alarm requires one 9 VDC
battery (included – mounted in the battery-compartment) .
Please note: At first time installation simply remove the plastic strip between the
terminals and the contact before mounting the smoke alarm .
Note: For optimal detection the smoke alarm should be installed in a suitable
location as described above .
After mounting and after every battery change, test the smoke alarm by pressing
the red test button until a penetrating, clear signal is heard . Make sure that the
red test button flashes once a minute . When the alarm is set-off, a penetrating,
rapidly pulsating signal is given out (min 95 dB/1m) . The alarm can be stopped by
pressing the red test button .
Maintenance
The following guidelines will help you care for the
JACOB JENSEN
TM
Smoke Alarm
so that you can enjoy using it for many years .
1 . Test the smoke alarm once every month – preferably once every week e .g .
when doing the vacuuming . This can be done by pressing the red test button
for at least 10 seconds or by blowing smoke into the alarm .
2 . Always test the smoke alarm when returning from a vacation or a trip .
3 . Clean the smoke alarm regularly by wiping with a soft cloth or vacuum
carefully . Do not immerse the smoke alarm in water .
4 . The lifetime of the battery is approx 1 year .
Approximately one month prior to the battery running flat, the alarm beeps
briefly once every minute . The alarm is still functioning but the signal indicates
that the battery needs to be replaced . The battery has to be 9V of a good
quality 6F22 or 6LR22 e .g . Duracell MN 1604 or Energizer 522 . Always test the
smoke alarm after changing the battery .
Specifications
Operating temperature:
0° C to + 40° C
Operating humidity:
Max . 85 %
Battery:
1 x 9 VDC type 6F22 or 6LR22
Life expectancy: 12 months
Radioactive material:
Americium-241, activity 37kBq
Disposal:
As household refuse or by returning the smoke
alarm to the importer .
Life expectancy:
Replace the product after 10 years .
Guarantee and Conditions
The manufacturer of this product guarantees (battery excepted) that the
product is free from material and manufacturing defects . This only applies if
the alarm is used in the normal way and maintenance carried out regularly . The
guarantee is also conditional on the smoke alarm not having been modified or
subjected to attempted repairs . Your statuary rights as a customer are in no way
compromised by this guarantee . The manufacturer and its suppliers accept no
liability whatsoever for any damage, expense, loss of profits or any other damage
incurred as a result of using this product . In the event of a defective smoke alarm,
please return to the place of purchase or to the importer .
Manufacturer: Homewatch Ltd .
Importer:
Bell Xpress A/S, Sletvej 50, DK-8310 Tranbjerg J
mail@bellxpress .dk – www .bellxpress .dk
Prior to fire
Plan and practise an escape route .
Agree a place to meet and remember that a smoke alarm does not put out a fire .
Is fire-fighting equipment available in your home? Remember that even a small
amount of smoke can be fatal .
In case of fire
Save – warn – put out
1 . Warn anyone who might be in danger .
2 . Notify the fire brigade . Always keep the number for the fire brigade by the
telephone .
3 . If possible, try to put out the fire with your fire fighting equipment . Isolate
the fire by closing doors and windows to the room on fire . Any closed door to
the room on fire can prevent the fire from spreading .
4 . Make sure that someone is available to guide the fire brigade when they
arrive .
If you are unable to get out of the house - go into a room with windows
facing the road, close the door and shout out for help . Don't waste time
trying to pick up valuables or possessions, your life is more important .
5 . Always close the doors behind you .
6 . Use towels, sheets or clothes to block any gaps under the door to help stop
smoke spreading into the room .
7 . Where smoke is dense, get down to the floor where the smoke is not usually
so thick as smoke rises .
8 . Cover your mouth and nose with a damp cloth .
9 . Stay calm - do not panic .