0,5 Bar

Min.

Max.

Pressure      Flow  Rates    

Dynamic Pressure

Recommendations for Proper Use

Installation  Instructions  

Self Closing Valve  

Maintenance

Water Temperature

3 Bar

1 Bar

Max.

2 Bar

8 L/m

0,5 Bar

60°C / 140° F

18 L/m

11 L/m

5 Bar

15 L/m

jaclo

 

industries 

 |  129 Dermody Street   Cranford, NJ 07016

p

 908.653.4433 | 800.852.3906   

f

 908.653.1717 | 800.852.4133

   

REVISED 7.01.15

JACLO.COM

   |   PG 2

To prevent impurities or debris from getting inside the product and causing functional problems, always flush out 

the system before connecting it to the supply pipes.  

It is recommended to install the filter at the system’s water 

intake.

To keep the diffuser clean and prevent lime scales from clogging the diffuser, we advise that you periodically rub 

the silicone nozzles to free them of the lime deposits.

IMPORTANT!!  TO ENSURE THE CORRECT INSTALLATION OF THE SHOWER COLUMN IT IS NECESSARY TO 

DECIDE IN ADVANCE WITH PLANNERS / INSTALLERS THE DESIRED DIRECTION OF THE SHOWERHEAD.  THE 

FINAL POSITION OF THE SHOWER COLUMN IS DETERMINED BY THE FIXATION OF THE BASE (3) TO THE 

FLOOR AS SHOWN IN FIGURE A.  ARRANGE WATER SUPPLY AT THE DESIRED LOCATION ACCORDINGLY.

1.  Mark the four base (3) fixation points on the floor, checking the correct positioning of the shower direction as 

per Figure A according to the determined shower direction.

2.  Drill 4 holes with a 14mm bid then insert anchors (8)

3.  Mount the straight pipe (2) with the base (3) and secure with M6 screws (6) with on/off valve (13) positioned in 

the same direction as foreseen for showerhead.

4.  Secure the straight pipe and base assembly on the floor with the M8x70 mm screws (4) as in Figure B.

5.  Assemble the curved shower pipe (1) with straight pipe (2) letting the supply flexible hose (5) slide down into 

the straight pipe.  Secure the two pipes at their connecting point with screws (12), Figure D.

6.  Screw supply flexible hose nut (5) on the on/off valve body (13), then fasten the cover plate (9) with M4 screw 

(12) as in Figure D.

7.  Align the straight and curved tubes (1 & 2) (an adjustment range ±5° allowed) and tighten the M4 adjusting 

screws (11).

8.  Connect water supply pipe to the water inlet (1) as illustrated in Figure E.

Where outdoor showers are fitted with self-closing on/off valve, the time adjusting screw is set by manufacturer.  

Gradually turn the adjusting screw clockwise or counterclockwise, until the desired flow time is achieved.  Time 

adjustment can bet set with a min. of 1 second and max. of 40 seconds.

IMPORTANT!! DO NOT FORCE THE SCREW CLOCKWISE, THIS CAN DAMAGE THE ADJUSTING MECHANISM

We recommend that you follow the maintenance instructions below to ensure that your product is safeguarded 

during the winter months.

1.  Empty the water supply that services the shower column at the end of the summer, before it starts to get cold.

2.  During the winter months, we recommend that you cover the column using the protective covering included, 

to protect it from inclement weather and humidity or remove it.  This is easy to do and will allow column to last 

longer.