![Jackson TempStar HH Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/jackson/tempstar-hh/tempstar-hh_installation-operation-and-service-manual_628906032.webp)
07610-002-23-32-AC
24
DETERGENT CONTROL
Detergent usage and water hardness are two factors that contribute greatly to how
efficiently this dishmachine will operate. Using detergent in the proper amount can
become a source of substantial savings. A qualified water treatment specialist can
determine what is needed for maximum efficiency from the detergent.
1. Hard water greatly affects the performance of the dishmachine, causing the
amount of detergent required for washing to increase. If the machine is installed
in an area with hard water, the manufacturer recommends the installation of
water treatment equipment.
2. Deposited solids from hard water can cause spotting that will not be removed
with a drying agent. Treated water will reduce this occurence.
3. Treated water might not be suitable for use in other areas of operation and it
might be necessary to install a water treatment unit for the water going to the
dishmachine only. Discuss this option with a qualified water treatment specialist.
4. Dishmachine operators should be properly trained on how much detergent is to
be used per cycle. Meet with a water treatment specialist and detergent vendor
to discuss a complete training program for operators.
5. These dishmachines require that chemicals be provided for proper operation
and sanitization and require the installation of third-party chemical feeders to
introduce these chemicals to the machine. Contact a chemical supplier with any
questions.
6. Water temperature is an important factor in ensuring that the dishmachine
functions properly. The machine's data plate details what the minimum
temperatures must be for the incoming water supply, the wash tank, and the
rinse tank. If minimum requirements are not met, there is a possibility that dishes
will not be clean or sanitized.
7. Instruct dishmachine operators to observe the required temperatures and to
report when they fall below the minimum allowed. A loss of temperature can
indicate a larger problem.
DETERGENT
CONTROL
OPERATION
Содержание TempStar HH
Страница 39: ...31 07610 002 23 32 AC 30 28 29 25 22 21 26 33 34 36 1 TOP MOUNT CONTROL BOX PARTS ...
Страница 46: ...07610 002 23 32 AC 38 1 5 4 2 3 6 7 10 8 9 HOOD ASSEMBLY PARTS ...
Страница 58: ...07610 002 23 32 AC 50 INLET PLUMBING PARTS 1 2 3 4 5 6 2 7 8 9 10 11 12 13 14 10 11 15 13 14 ...
Страница 60: ...07610 002 23 32 AC 52 OUTLET PLUMBING PARTS 1 2 3 4 5 2 2 ...
Страница 62: ...07610 002 23 32 AC 54 INLET PLUMBING HH E PARTS 1 13 9 2 3 4 5 6 7 5 8 10 11 12 2 14 ...
Страница 64: ...07610 002 23 32 AC 56 OUTLET PLUMBING HH E PARTS 1 2 3 4 5 7 6 ...
Страница 78: ...07610 002 23 32 AC 70 460 V MACHINE TRANSFORMER MOUNTING BOX PARTS ...
Страница 79: ...71 07610 002 23 32 AC EXHAUST FAN CONTROL OPTION PARTS ...
Страница 80: ...07610 002 23 32 AC 72 1 2 3 15 16 4 10 9 5 11 8 12 7 17 6 VENTLESS ENERGY RECOVERY ASSEMBLY PARTS ...
Страница 84: ...07610 002 23 32 AC 76 SCHEMATICS 208 230 V 50 60 HZ 1 PHASE ...
Страница 85: ...77 07610 002 23 32 AC SCHEMATICS 460 V 50 60 HZ 3 PHASE ...
Страница 86: ...07610 002 23 32 AC 78 SCHEMATICS LT NB 208 230 V 50 60 HZ 1 PHASE ...
Страница 87: ...79 07610 002 23 32 AC SCHEMATICS LT NB 460 V 50 60 HZ 3 PHASE ...
Страница 88: ...07610 002 23 32 AC 80 SCHEMATICS STEAM 208 230 V 50 60 HZ 1 3 PHASE ...
Страница 89: ...81 07610 002 23 32 AC SCHEMATICS SDI OPTIONS ...
Страница 90: ...07610 002 23 32 AC 82 SCHEMATICS DRAIN QUENCH OPTION ...