AJ-54C Series Technical Manual 7610-002-30-91
Issued: 03-22-2006 Revised: N/A
SECTION 6: PARTS SECTION
DRAIN QUENCH SYSTEM
92
From the existing drain, attach the two additional Tees (Item 7) using the 1-1/2” NPT Close Nipples (Item 8). Tighten the
Reducers (Items 6 & 9) into the Tees as shown above. Attach the Modified Compression Fitting (Item 10) into the 1-1/2” to 1/4”
Reducer (Item 9). Position the bulb of the thermostat (Item 1) so that it rests approximately 1/4” from the bottom of the Tee (Item
7). Tighten the Modified Compression Fitting (Item 10) as required.
Mount the Thermostat (Item 1) to the tub using the Thermostat Bracket (Item 2) and set it for 120°F - 140°F. Install the Solenoid
Valve (Item 3) to the second Tee (Item 7) and then attach to the incoming cold water line. Use pipe dope or thread tape as
required to prevent any leaks.
Thermostat
05930-121-67-72
Thermostat Bracket
05700-002-73-72
Solenoid Valve
04810-100-09-18
To Cold Water Supply
Nipple, Close, 1/2” NPT
04730-207-15-00
Valve, Check, 1/2”
04820-002-55-77
Reducer, 1-1/2” to 1/2”
04730-002-55-75
Tee, 1-1/2” x 1-1/2” x 1-1/2”
04730-011-69-93
Modified Compression
Fitting
05700-001-16-52
Reducer, 1-1/2” x 1/4”
04730-002-55-76
To Dishmachine Drain
To Drain
Nipple, 1-1/2” NPT
04730-207-40-00
Drain Quench Assembly
06401-002-44-07
Содержание Enodis AJ-54 Series
Страница 9: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Страница 24: ...16 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Страница 41: ...33 SECTION 3 PREVENTATIVE MAINTENANCE ...
Страница 45: ...37 SECTION 4 TROUBLESHOOTING SECTION ...
Страница 49: ...41 SECTION 5 SERVICE PROCEDURES ...
Страница 72: ...64 SECTION 6 PARTS SECTION ...
Страница 132: ...124 SECTION 7 ELECTRICAL SCHEMATICS ...
Страница 153: ...145 SECTION 8 JACKSON MAINTENANCE REPAIR CENTERS ...
Страница 160: ......