07610-004-29-29-D
6
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
On three-phase machines, imbalanced wild leg goes to L3
Also see the Motor Rotation section
NOTICE
DYNATEMP & DYNATEMP VER
Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service
contractor that your circuit protection is adequate and meets all applicable national and local codes. Numbers in this manual
are for reference and may change without notice
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
5.0 A
19.7 A
50.6 A
75.3 A
76.6 A
80.0 A
230
1
60 Hz
5.0 A
21.8 A
55.9 A
82.7 A
84.0 A
90.0 A
208
3
60 Hz
5.0 A
11.4 A
29.2 A
45.6 A
46.9 A
50.0 A
230
3
60 Hz
5.0 A
12.6 A
32.3 A
49.9 A
51.2 A
55.0 A
460
3
60 Hz
1.8 A
6.3 A
16.1 A
24.2 A
24.7 A
30.0 A
i
DYNATEMP NB
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
5.0 A
19.7 A
N/A
24.7 A
26.0 A
30.0 A
230
1
60 Hz
5.0 A
21.8 A
N/A
26.8 A
28.1 A
30.0 A
208
3
60 Hz
5.0 A
11.4 A
N/A
16.4 A
17.7 A
20.0 A
230
3
60 Hz
5.0 A
12.6 A
N/A
17.6 A
18.9 A
20.0 A
460
3
60 Hz
1.8 A
6.3 A
N/A
8.1 A
8.6 A
15.0 A
DYNATEMP S
Volts
Phase
Freq
Wash
Motor
Wash
Heater
Rinse
Heater
Total Load
MCA
MOP
208
1
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
230
1
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
208
3
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
230
3
60 Hz
5.0 A
N/A
N/A
5.0 A
6.3 A
15.0 A
460
3
60 Hz
1.8 A
N/A
N/A
1.8 A
2.3 A
15.0 A
Содержание DynaTemp NB
Страница 2: ......
Страница 37: ...07610 004 29 29 D 30 14 9 10 1 2 3 4 5 6 7 8 16 15 18 17 11 12 13 9 CANTILEVER ARM PARTS 3c 3d 3d 3a 3e 3b 19 ...
Страница 39: ...07610 004 29 29 D 32 11 10 9 12 13 19 20 4 18 17 16 14 15 1 2 3 5 6 7 8 21 TUB PARTS ...
Страница 41: ...07610 004 29 29 D 34 11 10 13 18 19 4 17 16 15 1 2 3 5 7 8 6 12 14 9 STEAM TUB PARTS ...
Страница 45: ...07610 004 29 29 D 38 PARTS WASH RINSE ARMS 1 2 3 4 5 6 7 8 9 10 11 ...
Страница 67: ......