TROUBLESHOOTING
TROUBLESHOOTING
OBSERVATION
POSSIBLE CAUSE
REMEDY
Prime switch does not acti-
vate sanitizer pump.
1. Faulty prime switch.
2. Faulty delime switch.
1. With the prime switch in the prime position, check for voltage
between the GREY and WHITE/RED wires to switch. If 120 V,
replace the switch.
2. With the delime switch in the DELIME position, check for
voltage between the WHITE/BLACK and WHITE/RED wires to
the delime switch. If 120 V, replace the delime switch.
Detergent not feeding; rinse-
aid feeds okay.
1. Misadjusted cam.
2. Faulty detergent microswitch
on cam timer.
1. Adjust detergent cam on cam timer.
2. When the detergent cam is in the home position, measure
voltage between ORANGE and GREY/ WHITE wires. If 120 V,
replace the microswitch.
Rinse-aid not feeding,
detergent feeds okay.
1. Misadjusted cam.
2. Faulty rinse-aid microswitch on
cam timer.
1. Adjust rinse-aid cam on cam timer.
2. When the rinse aid cam is in the home position, measure the
voltage between the ORANGE and ORANGE/YELLOW wires.
If 120 V, replace the microswitch.
Sanitizer pump does not run
during the cycle, but runs
when primed.
1. Loose or broken wire.
2. Faulty sanitizer microswitch on
cam timer.
1. Tighten connections to microswitch.
2. When sanitizer cam is in home position, measure voltage
between ORANGE and GREY wires on the microswitch.
If 120 V, replace switch.
Содержание CONSERVER XL2
Страница 38: ...07610 002 10 23 U 31 HOOD ASSEMBLY PARTS 1 6 7 4 2 5 3 9 8 2 3 2 10 11 6 7 8 9 2 12 13 2 14 7 9 8 6 15 10 2 ...
Страница 49: ...07610 002 10 23 U 42 WASH MANIFOLD ASSEMBLY PARTS 1 7 4 5 2 6 9 3 8 10 11 12 13 ...
Страница 52: ...07610 002 10 23 U 45 SCHEMATICS XL2 CML CMR 115 V 60 HZ 1 PHASE ...
Страница 53: ...07610 002 10 23 U 46 SCHEMATICS XL2 CML CMR 208 230 V 50 60 HZ 1 PHASE ...