HOW TO SPECIF
EXAMPLE:
Avenger™
HT
APPROXIMATE TOTAL LOAD AMPS
208/60/1
38.8
230/60/1
42.3
ELECTRICAL REQUIREMENTS
)
Wash pump HP
3/4
WATER REQUIREMENTS
Gallons per rack
1.1 gal
4.2 liters
Gallons per hour
26.4 gal
99.9 liters
Flow pressure (PSI)
15 - 25
Waterline size (IPS)
1/2
Drainline size OD
1 3/8
Highway 25E
P. O. Box 1060
Barbourville, KY 40906
Tel: 606-523-9795
Tel: 1-888-800-5672
Fax: 606-523-9196
E-mail: [email protected]
www.jacksonmsc.com
7610-003-34-02 (04/07)
Avenger™
HT
SHIPPING DIMENSIONS
WEIGHT
CLASS
CUBE
HEIGHT
WIDTH
DEPTH
248 lbs
( 112kg)
92.5
19.8
cu. ft.
38”
( 965 mm)
30”
(762 mm)
30”
(762 mm)
MACHINE DIMENSIONS
INSIDE
CLEARANCE
HEIGHT
INSIDE
CLEARANCE
WIDTH
INSIDE
CLEARANCE
DEPTH
DOOR
OPEN
DEPTH
WALL
CLEARANCE
INI
14-1/2
( 368 mm)
20”
(508 mm)
20”
( 508 mm)
42”
( 1067 mm)
1/4”
(6 mm)
OPERATING CAPACITY
Racks per hour
24
Dishes per hour
600
Glasses per hour
864
OPERATING CYCLE
Wash cycle (Seconds)
82
Drain time (Seconds)
28
Rinse time (Seconds)
10
Total cycle (Seconds)
120
OPERATING TEMPERATURES
Wash
150 ˚ F / 6 5 . 6 ˚ C
Rinse
1 8 0 ˚ F / 8 2 . 2 ˚ C
Door Open
24 3
16 [615mm]
33 5
16 [846mm]
TOP
FRONT
LEGEND:
A - Water Inlet - 1/2" Female Pipe Thread,
2 1/2" AFF (Connect to a true 1/2" ID
water line)
B - Electrical Connection
C - Drain Connection - 10' coiled drain hose.
Shipped inside machine. Must be installed
no more than 24" AFF.
All dimensions from floor can be increased
1" with adjustable feet supplied.
WALL
14
1
2
" [368mm]
DISH
CLEARANCE
2538 [644mm]
1658 [423mm]
1 9
16 [40mm]
A
11
4 [32mm]
B
2334 [604mm]
A
BACK
B
41
8 [105mm]
111
2 [292mm] 7
8 [22mm]
3 5
16 [84mm]
1
4 [6mm]
Wall Clearance
C
Jackson
™