Dri
ve
U
ni
t
60
1 4
[1530
mm
]
62
1 2
[1590
mm
]
29
[737mm
]
6 [
152
mm
]
10
[254mm
]
4 [
102
mm
]
7 [
178
mm
]
D
E
8 [
203
mm
]
L
24
[610mm
]
M
23
1 2
[599
mm
]
10
1 4
[261
mm
]
47
[1194
mm
]
A
53
3 4
[1365
mm
]
B
C
43
[1092
mm
]
75
1 2
[1919
mm
]
6 [
155
mm
]
36
[914mm
]
31
1 4
[797
mm
]
6
1 2
[165
mm
]
26
1 2
[673
mm
]
Fr
on
t V
ie
w
3/
4"
[19
mm
]
Table
T
urndow
n
Flange
3
/4"
Ma
x
21"
[533
mm
]
Ra
ck
Rail
Heigh
t
A
bo
ve
Di
sh
tabl
e
1/
4"
[6
m
m
] -
5
/16
" [
8mm
]
Ra
ck
Rai
l
Tu
b
Tabl
e
U
se
S
ilic
one
S
eale
r
Be
tween
T
able
an
d
Lip
o
f Ma
chine
to
Pr
ev
en
t Lea
kag
e
Recommended
Table
Fab
ricatio
n
No
te
: T
ub
W
ill
Acc
ep
t
a T
able
F
lang
e
Up
to
24
7
/8
"
[632
mm
]
R
igh
t t
o Le
ft
Legend
to
Drawin
g
A
- Ma
chine
wa
te
r inle
t 3
/4"
N
P
T,
110°
F - 140°
F
Hi
-te
mp
,140°
F
Low-
temp
minimu
m
B
- E
le
ct
ric
al
c
onne
ct
io
n
C
-
Drain
c
onne
ct
ion
1
-1
/2
" N
PT
D
-
V
en
t co
lla
r -
O
pt
iona
l
E
- V
en
t c
owl
st
andar
d
F
- 3
/4"
N
P
T
180°
F W
at
er
Inle
t f
or
wa
sh
tan
k
f
ill, f
inal
rin
se
, &
tan
k
hea
ting
. F
rom
ga
s
boo
st
er
hea
te
r. I
nt
er
conne
ct
ing
ho
se
pro
vided
b
y
manu
fa
ct
urer
.
G
- 3
/4"
N
P
T
140°
F W
at
er
inle
t f
or
ga
s
boo
st
er
hea
ter
.
H
-
3/
4"
N
P
T
180°
F W
at
er
O
ut
le
t
conne
ct
ion
to
line
on
di
shma
chine
.
Conne
ct
ion
ho
se
p
ro
vided
b
y
manu
fa
ct
urer
.
J
- 3
/4"
N
P
T G
as
Conne
ct
io
n
K
- 4"
O
D
V
en
t pipe
c
onne
ct
ion
. F
lue
to
be
in
st
alled
to
m
ee
t lo
cal
c
ode
s
by
in
st
alling
c
on
tra
ct
or
.
L
- Pr
ewa
sh
wa
te
r inle
t 3
/4
" N
PT
110°F
-140°
F
M
- Cold
wa
te
r t
hermo
st
at
plumbin
g
conne
ct
ion
3
/4"
NP
T
- O
pt
iona
l
No
te
: A
ll
ve
rti
cal
dimen
sion
s
are
+
/-
1/
2"
fr
om
floo
r due
to
adju
st
able
bulle
t f
ee
t.
Table
to
T
abl
e
O
veral
l
4"
(102
mm
) wide
x
16"
(406
mm
)
long
cu
tou
t in
Ven
t Cowl
/Spla
sh
Sh
ield
. Sh
ipped
wi
th
Co
ver
Pla
te
.
86
[2182
mm
]
94
[2386
mm
]
102
[2589
mm
]
B
Fl
oo
r Si
nk
O
r Drai
n
W
ith
3"
(76
mm
)
M
ini
mu
m
D
rain
Lin
e
25
[637mm
]
8
[204
mm
]
21
[535
mm
]
20
3 4
[527
mm
]
8
3 4
[222
mm
]
11
3 4
[298
mm
]
14
3 4
[375
mm
]
6 [
152
mm
]
30
[763mm
]
14
[357mm
]
7
1 4
[185
mm
]
1
1 4
[35
mm
]
K
J
H
G
A
Pr
ewa
sh
Pl
an
V
iew
Se
ct
io
n
wi
th
Cold
W
at
er
T
hermo
st
at
16
3 4
[425
mm
]
16
1 4
[415
mm
]
L
M
22
[557
mm
]
64
[1626
mm
]
Ba
se
Uni
t
Pr
ewa
sh
K
J
H
G
C
R
igh
t S
id
e
34
[864mm
]
8
1 2
[217
mm
]
21
[533mm
]
25
[635mm
]
12
[307mm
]
25
[635mm
]
B
Di
sh
Clea
ran
ce
Dri
ve
U
ni
t
Le
ft
Sid
e
66
1 2
[1692
mm
]
3 [
79mm
]
1 2
[15
mm
]
84
[2134
mm
]
A
M
L
W
ith
Doo
rs
O
pe
n
Rear
o
f
Ma
ch
in
e
6 [
152
mm
]
1 [
25mm
]
65
1 2
[1665
mm
]
SECTION 1: SPECIFICATION INFORMATION
AJ-86 GAS - RIGHT TO LEFT
14
Содержание AJ-100CE
Страница 9: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Страница 37: ...29 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Страница 52: ...44 SECTION 3 PREVENTATIVE MAINTENANCE ...
Страница 57: ...49 SECTION 4 TROUBLESHOOTING SECTION ...
Страница 61: ...53 SECTION 5 PARTS SECTION ...
Страница 100: ...SECTION 5 PARTS SECTION 92 DRIVE ASSEMBLY 1 2 3 4 11 12 13 18 17 14 15 16 5 6 7 8 9 10 See Detail A ...
Страница 121: ...113 SECTION 6 ELECTRICAL SCHEMATICS ...
Страница 154: ...146 SECTION 7 JACKSON MAINTENANCE REPAIR CENTERS ...
Страница 161: ......