200 Series Technical Manual
7610-100-45-00 Rev. E (02/10/2006)
SECTION 1: SPECIFICATION INFORMATION
OPERATING CAPACITIES
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY
(RACKS/HOUR)
RACKS PER HOUR
57
DISHES PER HOUR
1425
GLASSES PER HOUR
1425
OPERATING CYCLE
(SECONDS)
WASH TIME
45
RINSE TIME
11
TOTAL CYCLE
58
TANK CAPACITY
(GALLONS)
WASH TANK (MINIMUM)
8.0
BOOSTER TANK
3.0
WASH PUMP CAPACITY
GALLONS PER MINUTE
150
TEMPERATURES
WASH---°F (MINIMUM)
150
RINSE---°F (MINIMUM)
180
WASH---°F (MINIMUM) (200 LT)
130
RINSE---°F (MINIMUM) (200 LT)
130
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided on
this page is for reference only and may be subject to
change without notice.
STEAM REQUIREMENTS
COIL SIZE
3/4”
STEAM FLOW PRESSURE (P.S.I.)
10-20
CONSUMPTION @ 15 P.S.I. (LBS/HR)
45
WATER REQUIREMENTS (MINIMUM)
INLET TEMPERATURE (200)
180°F
INLET TEMPERATURE (200B)(40° Rise) 140°F
INLET TEMPERATURE (200B)(70° Rise)
110°F
INLET TEMPERATURE (200LT)
140°F
INLET TEMPERATURE (200S)
110°F
GALLONS PER HOUR
52.2
GALLONS PER RACK
0.92
WATER LINE SIZE NPT
3/4”
DRAIN LINE SIZE NPT
1 1/2”
FLOW PRESSURE P.S.I. (Optimum)
20
A
5
MINIMUM CHLORINE REQUIRED (PPM)(200LT)
50
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HP
1
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition.
Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical
service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These
numbers are provided in this manual simply for reference
and may change without notice at any given time.
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
MODEL
VOLTS PH HZ
RATINGS
AMPS
CIRCUIT
200B
208
1 60 12KW@230 72 A 90 AMP
200B
230
1 60 12KW@230 79 A 100 AMP
200B
208
3 60 12KW@230 40 A 50 AMP
200B
230
3 60 12KW@230 44 A 60 AMP
200B
460
3 60 12KW@230 22 A 25 AMP
200B
208
1 60 14KW@230 79 A 100 AMP
200B
230
1 60 14KW@230 87 A 110 AMP
200B
208
3 60 14KW@230 44 A 60 AMP
200B
230
3 60 14KW@230 49 A 70 AMP
200B
460
3 60 14KW@230 25 A 36 AMP
200
208
1 60 N/A
29 A 40 AMP
200
230
1 60 N/A
31 A 40 AMP
200
208
3 60 N/A
15 A 20 AMP
200
230
3 60 N/A
16 A 20 AMP
200
460
3 60 N/A
8 A 15 AMP
200/LT
208
1 60 N/A
29 A 40 AMP
200/LT
230
1 60 N/A
31 A 40 AMP
200/LT
208
3 60 N/A
15 A 20 AMP
200/LT
230
3 60 N/A
16 A 20 AMP
200/LT
460
3 60 N/A
8 A 15 AMP
200S
208
1 60 N/A
7 A 15 AMP
200S
230
1 60 N/A
7 A 15 AMP
200S
208
3 60 N/A
4 A 15 AMP
200S
230
3 60 N/A
4 A 15 AMP
200S
460
3 60 N/A
4 A 15 AMP
2
Содержание 200B
Страница 2: ......
Страница 6: ...1 SECTION 1 SPECIFICATION INFORMATION...
Страница 10: ...5 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS...
Страница 16: ...11 SECTION 3 PREVENTATIVE MAINTENANCE...
Страница 18: ...13 SECTION 4 TROUBLESHOOTING SECTION...
Страница 21: ...16 SECTION 5 SERVICE PROCEDURES...
Страница 32: ...27 SECTION 6 PARTS SECTION...
Страница 54: ...49 SECTION 7 ELECTRICAL SCHEMATICS...
Страница 57: ......