PERFORMANCE/CAPABILITIES
OPERATING CAPACITY
(RACKS/HOUR)
RACKS PER HOUR
24
DISHES PER HOUR
192
GLASSES PER HOUR
600
OPERATING CYCLE
(SECONDS)
WASH TIME
106
RINSE TIME
14
TOTAL CYCLE TIME
120
TANK CAPACITY
(GALLONS)
WASH TANK (MINIMUM)
3.4
RINSE TANK
1.4
TEMPERATURES
WASH---°F (MINIMUM)
150
RINSE---°F
180
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER
1/2
VOLTS
PHASE
AMPS
208 1
23.2
240 1
20.4
WATER REQUIREMENTS
INLET TEMPERATURE
140°F
GALLONS PER RACK
.59
GALLONS PER HOUR
14.2
WATER LINE SIZE I.P.S. (Minimum)
1/2”
DRAIN LINE SIZE I.D.
1”
FLOW PRESSURE P.S.I. (Optimum)
20
FRAME DIMENSIONS
WIDTH
19”
DEPTH
20”
HEIGHT
29 5/8”
MAXIMUM INSIDE CLEARANCE
14”
SPECIFICATIONS of CJ-16