12
Figure 9
Natural Gas Connection:
FUEL TYPE:
T
he following instructions are for Natural Gas configured grills ONLY.
Operating Pressure = 4” WC
.
BUILT IN NATURAL GAS HOOK
-
UP: (Fig. 9)
1.
The piping up to the gas grill is the responsibility of the installer and piping should be located as shown below.
2.
The connector must not pass through a wall, floor, ceiling or partition, and is protected from damage.
3.
Do not use a hose to connect the unit except to connect the cylinder regulator to the piping system.
4.
The gas supply pipe must be sufficiently sized to supply the BTU/h specified on the rating plate, based on the
length of the piping run.
!WARNING!
1 Never insert any foreign objects in the quick release or Natural Gas hose, as this may cause
leaks.
2 Pressure from the gas source for this grill and its appliance regulator (set at 4” WC) MUST
NOT exceed 7 inches of Water Column; using a grill at higher pressures could result in
property damage, and injury or death.**
3 Do NOT use this grill until leak tests have been completed.
4. If a gas leak is detected and cannot be stopped, call the fire department immediately
.
** NOTE; this is the maximum inlet pressure rating for the included Natural Gas Regulator,
part number JF
-
99
Typical Natural Gas Connection
CAUTION:
Provide adequate ventilation holes in the enclosure for safety
purposes in the event of a gas leak.
Regulator set at
4” WC (Natural
Gas)
Typical Rear gas
connection:
Installer supplied
gas shutoff valve
(must be in an
accessible
location)
Typical
Bottom Gas
connection
Installer
supplied gas
shutoff valve
(must be
easily
accessible)