11
because surplus gas may leak from safety relief valve. The safety relief valve on a
L.P. tank could activate to release gas and cause a fire.
3. The spare L.P. tank must have safety caps installed on the L.P. tank outlet.
4. If any gas leaks are found on the spare L.P. tank, immediately go away from it and
call the fire department.
VERY IMPORTANT: DISCONNECT THE TANK WHEN THIS GRILL IS NOT IN USE.
To disconnect L.P. gas tank:
1. Turn all the knobs off.
2. Turn the tank valve off fully (turn clockwise to stop).
3. Detach the regulator assembly from tank valve by turning the quick coupling nut counterclockwise.
4. Install the protective cap back L.P. tank valve.
Natural Gas Conversion
Tools required to convert this grill from Propane Gas to Natural Gas (tools not provided):
1. # 2 Phillips screwdriver
2. 7 and 9 mm wrenches
The NG conversion kit is supplied with this grill:
Item
Description
Quantity
1
2 pcs
2
1 pc
The outdoor gas appliance and its individual shut off valve must be disconnected from the gas supply
piping system during any pressure testing in excess of ½ psi (3.5 kPa).
The outdoor gas appliance must be isolated from the gas supply by closing its individual manual shut off
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than
½ psi (3.5 kPa).
MAIN BURNER CONVERSION
1. Remove the cooking grids and flame diffusers.
2. Remove the cotter pins that hold the main burners to the firebox rear wall.
3. Using a 7 mm wrench undo all of the main burner orifices from the underside of the control panel or
through the front of the firebox.
NG Orifice, Main Burner: #53 drill size
NG Orifice, Rotisserie Burner: #53 drill size
Содержание JLS-LP
Страница 6: ...6 Exploded View Parts List ...