background image

 

10

 / 

14

 

 

4

Descending  accounting  to  0,  alarm  and 

stop running   

5

  Ascending accounting to full, remind and 

keep running   

6

  Descending  accounting  to  0,  alarm  and 

keep running 

Note: press P shortly to cancel alarm 

P91 

Stitch count value 

0-9999 

 

P92 

Piece count value 

0-9999 

 

P93 

Voice switch 

0-1 

0

  Off      1

  On 

P94 

Boot language switch 

0-1 

0

  Off      1

  On 

P95 

Language selection 

0-1 

0

  Chinese      1

  English 

P97 

Main part stitch length 

35 

0-50 

 

P98 

Condense stitch mode selection 
 

0-3 

0-Close   
1-Front  encryption  2-Back  encryption 
3-Front and back encryption 

P99 

Stitch Lock 

0-1 

0

  Off      1

  On 

P100 

Manual inverted seam switchin
g speed limit function selection 

0-1 

0

  Off      1

  On 

P101 

1/2 stitch length key mode 
change EN 

0-1 

0

  Off      1

  On 

P107 

Safety needle break selection 
switch 

0-1 

0

  Off      1

  On 

P108 

Safety needle break starting 
mechanical angle 

20 

0-359 

 

P109 

Safety needle break finished 
mechanical angle 

90 

0-359 

 

P110 

Fixed stitches trimmer in 
sewing and then bartack 
selection switch 

0-1 

0

  Off      1

  On 

P116 

Single seaming function switch 

0-1 

0

  Off      1

  On 

P123 

Duty cycle of full opening 
phase of the presser foot 

100 

0-100 

 

P124 

Starting condense stitch length 

0 - 50 

 

P125 

Starting condense stitch 
direction 

0-1 

0- forward stitch 1- reverse stitch 

P126 

Starting condense stitch speed 

1000 

100 - 2500 

 

P127 

Starting condense stitch needle 
number 

0 - 12 

 

P128 

Ending condense stitch needle 

0 - 50 

 

P129 

Ending condense stitch speed 

1000 

100 - 2500 

 

P130

 

Ending condense stitch needle 
number 

0 - 12 

 

P131

 

Ending condense stitch needle 
number 

0 - 1 

0- forward stitch 1- reverse stitch

 

Содержание ZB-A4F

Страница 1: ...rference or electric leakage accidents make a good grounding work The grounding wire of the power cord must be firmly connected to the earth All parts for maintenance must be supplied or approved by the Company before they can be used The power must be turned off and the plug unplugged before any maintenance action is performed There is a high voltage danger in the control box You must shut down t...

Страница 2: ...ating Socket of Electromagnet LED Lamp and machine head 1 2 2 controller connection plug definition If it cannot be inserted normally please check the plug and socket match or not the direction of the insertion or the direction of the needle is correct or not ...

Страница 3: ...troductions 2 1 display introduction According to the working status of the system the LCD of the operation panel will display the current sewing status including the needle position indicate The appearance of the operation panel is shown as below 2 1 appearance of operation panel 2 2 function declaration of each key Key Name Indicate 1 Stitch length adjustment key Stitch length adjustment key pre...

Страница 4: ...responding key to set A B C D 2 Press the key for long time icon is lit means now is Several Segment Tacking mode choose corresponding key to set all steps and all stitches of each step 9 Lock stitch key Needle position section key Press short time to this key the lock stitch function will switch to front lock rear lock front and back lock close Press long time to enter needle position function 10...

Страница 5: ...ne to enter technician parameter mode The methods is same as parameter mode 3 3 Speed adjustment Press and to adjust the speed For up to adjust fast for down to adjust slow each adjustment value is 50 3 4 Factory setting Press the for a long time back to the factory setting 3 5 Enter monitoring system Press to enter this mode press up and down key to adjust this parameter press P then can log out ...

Страница 6: ...ngth to 5mm long press stitch length plus or press stitch length minus to enter the sewing parameter modification interface In the parameter modification interface short press the or key to switch the modified parameter position press the or key to modify the stitch length compensation parameter size P171Stitching needle length compensation ratio P172Reverse stitching needle length compensation ra...

Страница 7: ...1 Max speed of manual reverse sewing r min 2800 200 3200 P22 Value of backstitch during half stitch 8 0 9999 P23 curve mode of pedal 0 0 3 0 straight 1 Slope 2 curve square extraction of a root 3 S curve P24 Pedal position of trimming 550 0 4095 P25 Stitch compensation of back tacking 1 0 0 10 P26 Stitch compensation of back tacking 2 0 0 10 P27 Sensor press foot lifter mode selection 0 0 1 0 clos...

Страница 8: ...f down needle position 176 0 359 P34 Multi segment sewing motion mode selection 0 0 1 0 one key start function off 1 one key start function off P35 Thread clamp switch 1 0 1 P36 Threads testing ending angle 25 1 360 P37 Thread clamp magnet closing time 4 2 10 P38 Trimmer switch 1 0 1 0 off 1 on P39 Press foot lifter in halfway 0 0 1 0 off 1 on P40 Switch of auto press foot lifter after trimming 0 ...

Страница 9: ...ow speed 800 0 4095 P74 Max value of pedal analog 4000 0 4095 P75 Setting of pedal back to middle position 1650 0 4095 P78 Thread clamp ending angle 130 10 359 P79 Thread clamp end angle 320 0 359 P80 Trimming starting angle 0 0 359 P81 Trimming strength angle 100 0 359 P82 Trimming ending angle 180 0 359 P83 Pedal presser foot confirmation time ms 150 1 500 P84 The confirmation time of Safety swi...

Страница 10: ...ength key mode change EN 0 0 1 0 Off 1 On P107 Safety needle break selection switch 1 0 1 0 Off 1 On P108 Safety needle break starting mechanical angle 20 0 359 P109 Safety needle break finished mechanical angle 90 0 359 P110 Fixed stitches trimmer in sewing and then bartack selection switch 0 0 1 0 Off 1 On P116 Single seaming function switch 0 0 1 0 Off 1 On P123 Duty cycle of full opening phase...

Страница 11: ... foot height adjust 0 999 999 P177 Press down speed 300 50 1000 P179 Press up speed 400 50 1000 P181 Press height limit 13 0 13 P182 Stepmotor press up time 10 0 9999 P183 Stepmotor stitch act angle length change 150 0 359 P184 Stepmotor keep current 28 1 50 P185 Stitch length keep time 0 0 10 P186 Stepmotor target location adjust 6 0 30 P187 Stepmotor current limit 70 60 80 P193 1 2 stitch length...

Страница 12: ...rovider or call 4008876858 Err 05 Overvoltage during operation Disconnect the controller power and check whether the input power voltage is higher than 264V If so please restart the controller after the voltage returns to normal If the voltage returns to normal it still does not work properly after the controller starts up Please contact your local service provider or call 4008876858 Err 06 Electr...

Страница 13: ...roller still does not work properly please contact your local service provider or call 4008876858 Err 15 Arm shaft motor overspeed protection Err 16 Arm shaft motor reverse Err 17 Pandel date read write failure Turn off the system power and then turn on the power again after 30 seconds If the controller still does not work properly please contact your local service provider or call 4008876858 Err ...

Страница 14: ...tions If so replace it in time 3 If the system still does not work properly after troubleshooting and restart Please contact your local service provider or call 4008876858 Err 29 Reverse stitch stepping motor encoder AB signal abnormal 1 Check whether the backstitch step motor swing seat and teeth are stuck After the normal state is restored restart the system 2 Check whether the backstitch step e...