Troubleshooting
Err-09
Brake circuit
failure
1, check the electrical control box in the cement resistance plug is
off 2, check the cement resistance is burst 3, replace the cement
resistance 4, replace the control box
Err-10
HMI communication
failure
1, check the control panel and the electric control box connection
is off, loose, broken 2, restore the factory 3, replace the panel 4,
replace the control box
Err-11
Head stop
signal
failure
1, check the plug is loose 2, replace the encoder 3, replace the
control box
Err-12
Motor initial angle
detection
fault almost does not appear.
Err-13
Motor HALL fault
1, restore the factory settings 2, replace the motor encoder 3,
replace the control box.