background image

5

Control Panel

 

CAUTION:

Remove  fuse,  or  turn  circuit  breaker  off, 
whilst installing Controls and Electrics.

Select a position for the Control Panel (key 31) that 

• 

is  convenient  for  both  standing  and  seated  users, 
and  which  allows  you  to  run  the  10ft  (3m)  control 
cable to the toilet.
To use the Jabsco Fascia Panel provided, (key 32) 

• 

drill a 5/8" (16mm) hole for the 6 way control cable 
connector.  Screw  the  control  panel  (key  31)  onto 
selected  location  with  suitable  counter  sunk  head 
screws. Clip on fascia panel (key 32).
To use Gewiss fascia panels remove the four screws 

• 

tabs  (see  picture  below).  Cut  a  rectangular  hole 
53mm  x  92mm.  Fix  panel  (key  31)  to  selected 
location with four counter sunk head screws. Clip on 
Gewiss fascia panel. 
To use Vimar fascia panels remove the four screw 

• 

tabs  (see  picture  below)  Cut  a  rectangular  hole 
53mm x 92mm. Place adaptor (key 33) onto panel 
(key 31) and screw into place with four counter sunk 
head screw. Clip on Vimar panel onto adaptor.
Slide  the  Heat  Shrink  Sleeve  (key  30)  over  the 

• 

control cable. Plug in the 6 way control cable to the 
toilet, and carefully use a hot air gun or hairdryer to 
seal  the  Heat  Shrink  Sleeve  over  the  6  way 
connector.
Note  that  the  toilet  has  2  other  leads  -  Red  and 

• 

Black. Connect your boat’s Positive (+) feed to the 
Red (+) lead, and your boat’s Negative (-) return to 
the Black (-) lead.

Foot-switch

Connect your boat’s Positive (+) feed to the Red (+) 

• 

lead,  and  your  boat’s  Negative  (-)  return  to  the 
Black (-) lead.

Securing the toilet

Bolt  down  the  base  toilet  ensuring  that  the  Foot-

• 

switch (key 24) and/or the blank (key 28) are located 
correctly.  Make  sure  that  the  cable  from  the  Foot-
switch is located in the guide and not trapped.
With control panel fit 2 blanks, with Foot-switch fit 1 

• 

blank on respective side.
Before fitting the seat and lid, if required, you may 

• 

rotate  the  upper  part  of  the  toilet  and  offset  the 
angle of the seat to the base. 
To rotate the top, loosen the two screws in the clamp 

• 

(key 4) and rotate to the desired position, retighten 
clamp screws.
The top may be rotated 68° each side but, you will 

• 

need to fit a longer 19mm (¾”) inside diameter rinse 
inlet pipe (key 15).

Testing

Ensure that the battery is fully charged, and that the 

• 

circuits are live.
Open both seacocks.

• 

Refer to the next section - OPERATING INSTRUCTIONS.

• 

To  prime  the  Rinse  pump  on  first  installation, 

• 

operate  the  'Quick  Flush'  function  (for  the  control 
Panel version several times until water flows into the 
toilet bowl. The foot-switch may have to be pressed 
several times until water flows into the bowl.

Safet y

Ensure  that  this  INSTRUCTION  MANUAL  reaches  the 
owner,  skipper  or  operator  of  the  craft  as  it  contains 
essential safety information.

ON COMPLETION - CLOSE BOTH SEACOCKS

OPERATING INSTRUCTIONS

The toilet is one of the most used pieces of equipment 
on your boat. Correct operation of the toilet is essential 
for the safety and comfort of your crew and craft.

Open  inlet  and  outlet  seacock  (and  secondary 

• 

valves if fitted).
Use good quality hard or soft household toilet paper, 

• 

but do not use more than necessary.

 

CAUTION:

Do  not  put  anything  in  the  toilet  unless 
you  have  eaten  it  first,   except  toilet 
paper.

Cut along indented lines on 
either side and pull off screw 
tabs

Screw into place with 
four counter sunk head 
screws

ELECTRICAL SPECIFICATIONS

Voltage

Amp Draw

Fuse/Breaker

Wire size mm

2

 (AWG) per metre (foot) of length*

0-4 m (0-13 ft)

4-6 m (13-20 ft)

6-12 m (20-40 ft)

12-18 m (40-60 ft)

12 Vdc

20

25 amp

   

6

 mm

2

 (#

8

)

10

 mm

2

 (#

6

)

20

 mm

2

 (#

4

)

25

 mm

2

 (#

3

)

24 Vdc

10

15 amp

2.5 mm

2

 (#1

2

)

  4 mm

2

 (#1

0

)

  6 mm

2

 (#

9

)

    8 mm

2

 (#

8

)

* Wire length is the total distance from the battery to the flush pump and back to the battery

Содержание 58500 Series

Страница 1: ...ve the bowl dry or by pressing the foot switch once more leave the bowl wet ready for the next user Note The correct use of the toilet is to Press the foot switch and add water to the bowl 1 Use the toilet 2 Press the foot switch to add water and 3 Then discharge 4 Touch pad controller The lite flush toilet features a multi function one touch control pad offering four options fill quick flush flus...

Страница 2: ...itch and discharge hose positions may be adapted to replace either a left hand or right hand manual toilet The seat and lid are delivered boxed and unfitted for their protection Key numbers eg key 31 are references to the exploded diagram on the back page Location Select a location that will give sufficient clearance all round and above the bowl The mounting surface must be flat rigid and strong e...

Страница 3: ...ugh hull fitting irrespective of whether inlet or outlet SPECIAL NOTE 1 The smaller bore inlet pipework is more hazardous than the larger outlet pipework Unless there is a ventilated anti syphon loop in the inlet pipework water will flow into the bowl whenever both the inlet seacock is open and the rim of the bowl is below the actual waterline SPECIAL NOTE 2 Making a loop in the hose without fitti...

Страница 4: ...outlet seacock by the most direct route Option 3 Toilet discharging into holding tank AND top of holding tank above non return valve at any time YOU MUST FIT a 1 38mm Vented Loop fitting Jabsco part number 29015 0010 If there is ANY possibility that the discharge non return valve may be below the top of the tank at ANY time a ventilated anti syphon loop must be fitted in the outlet pipework to ens...

Страница 5: ... switch fit 1 blank on respective side Before fitting the seat and lid if required you may rotate the upper part of the toilet and offset the angle of the seat to the base To rotate the top loosen the two screws in the clamp key 4 and rotate to the desired position retighten clamp screws The top may be rotated 68 each side but you will need to fit a longer 19mm inside diameter rinse inlet pipe key...

Страница 6: ...ick liquid toilet cleaners or neat bleach They may damage the valves gaskets and seals SERVICING INSTRUCTIONS Jabsco Lite Flush electric toilets do not normally require maintenance during the season provided that they are winterised in the autumn Regularly check all fastenings for tightness and leaks WARNING HAZARD RISK Leaks REPAIR LEAKS IMMEDIATELY If the toilet is connected to ANY through hull ...

Страница 7: ...e 4 retaining screws key 13 REASSEMBLE IN REVERSE ORDER NOTE Ensure flush pump vibration washers key 13 are correctly located Apply a light smear of white lubricating grease to the interior of the bowl seal key 11 Do not over tighten any mounting screws SERVICING AND TESTING Hoses Examine all hoses throughout their length for chafe kinks and splits under hose clips Check all hose clips for corrosi...

Страница 8: ... 29 30 33 31 32 34 35 Exploded View Spare Parts Service Kits Available Kit Description Part No A Hose Kit 58550 1000 B Pump Assembly Kit 12v 58540 1012 Pump Assembly Kit 24v 58540 1024 C Control Kit Footswitch 58555 1000 D Control Kit Panel 58029 1000 Key Description Qty Part Number A B C D 1 Seat and Lid 1 58530 1000B 2 Top 1 3 Intake Elbow and Clip 1 4 Seat and Lid Clamp Kit 1 5 Top Bowl Seal 1 ...

Отзывы: