ELECTRICAL CONNECTIONS - Select a location for

the switch and instruction plate, making sure wire leads

from both the toilet and power source can be routed to

the switch. Ensure the panel where installing switch is no

more than 1" thick. Drill a 5/8" mounting hole and install

switch and instruction plate. Use stranded copper wire of

the correct size (determined from the electrical specifi-

cations chart) to connect one side of the switch to the

positive power source. An appropriate size fuse or equiv-

alent circuit breaker (determined from electrical specifi-

cations chart) must be installed in the positive power

lead within seven inches of the power source. Connect

the other side of the switch to the orange (positive) motor

lead. Connect the black (negative) motor lead to the neg-

ative side of the battery or grounded buss bar.
NOTICE: Correct motor polarity (orange to positive,

black to negative) is important. Reverse polarity can

damage motor and void warranty. Full voltage at the

motor is required to properly operate the Electric Toilet.

The toilet must be wired in a circuit independent of all

other accessories.

ELECTRICAL SPECIFICATIONS

AMP

FUSE

WIRE SIZE PER FEET OF RUN*

V OLTAGE

DRAW

SIZE

0'-10'

10'-15'

15'-25' 25'-40' 40'-60'

12 Vdc

16

25

#12

#10

#10

#8

#6

24 Vdc

8

15

#16

#14

#12

#10

#10

* Length of run is total distance from power source to product and back to ground.

OPERATING INSTRUCTIONS

Make sure inlet and outlet seacocks are all open; push button

to operate. Operate until bowl is completely flushed and

discharge pump has scavenged water from bottom of bowl.
The Jabsco electric marine toilet will provide years of trou-

blefree service if properly used. It will handle waste and toi-

let tissue. It will NOT handle rags, sanitary napkins or hard

solid objects.
If bowl does not pump out and begins to fill, partially close

inlet valve until bowl is cleared and completely pumped

out. Then operate for a few seconds with both valves open

to clear entire toilet and discharge system. For maximum

safety, when toilet is not in use or vessel is unattended,

close both the inlet and discharge seacocks.

To drain for winter lay-up, close inlet valve and operate for

a few seconds until all water is pumped out.
After long periods of non-use, toilet and pump may dry out.

To ease initial start-up, put about one quart of water in bowl

and let stand awhile before initial use.

DISASSEMBLY

Disconnect pumping inlet and discharge hoses. Remove

four screws, Key No. 25, pull out complete motor, pump

and macerator assembly. If assembly does not slide out

easily, push forward and pull back sharply several times to

free macerator housing from base.
Remove discharge port, Key No. 12, and joker valve.

Unscrew chopper plate, Key No. 14, by turning counter-

clockwise, facing plate. Prevent shaft from turning by plac-

ing screwdriver in discharge port and locking centrifugal

impeller blade. Remove macerator housing. Loosen

impeller set screw and slide impeller off motor shaft.

Remove four flathead screws and two washers, Key Nos.

20, 21, & 22. Remove the plastic wearplate, Key No. 23,

with sealing sleeve, Key No. 19, and gasket, Key No. 26.

Slide pump assembly off motor shaft. Replace all worn or

damaged parts, clean remaining parts.

ASSEMBLY

Press seal into body with lip facing impeller; be careful

not to cock seal in bore. Install pump body on motor and

position on register. Lubricate impeller bore with pump

grease and install impeller. Position the gasket against

the body and install the wearplate ensuring the two plas-

tic sealing washers are under the heads of the top and

bottom screws. NOTE: The current plastic wearplate

supercedes the earlier brass wearplate and with it the

stainless steel wearplate is no longer used. Slide the

rubber sealing sleeve on the motor shaft and push it into

its recess in the wearplate. Relocate centrifugal impeller

on shaft, about 1/8" from the wearplate, and tighten set

screw. Place macerator housing over shaft and centrifu-

gal impeller, put lock washer on end of shaft and screw

chopper plate on shaft and tighten. Install O-ring in O-

ring groove in wearplate surface, a little grease will help

hold in place, make sure inside body surfaces are clean,

line up slot in base with key on macerator housing, slide

pump assembly into base and tighten with the four

screws. Turn motor on for one or two seconds to be sure

centrifugal impeller is free.

WARNING

!

Flood hazard.  Close inlet and outlet 

seacocks prior to disassembling toilet.  

Failure to do so can result in flooding 

which can cause loss of property and life.

37068-0000

SOLENOID

EXPLODED V IEW

PARTS LIST

Qty. 

Part 

Key

Description

Req.

Number

1  Seat & Cover 

Note - 2018 models identified with Jabsco logo on top of bowl.                    

    Compact 

             1        29097-1000

    Regular (Pre 2018) 

             1        29127-1000

    Regular (2018 onwards)  

             1        58104-1000

    Soft Close (2018 onwards) 

             1        58104-2000

2  Bowl 

    Compact 

             1        29096-1000

    Regular 

             1        29126-1000

3. Hinge Set (1 PAIR)

Compact (ALL VARIANT)   

1       29098-1000

Regular (Pre 2018) 

1       29098-2000

Regular (2018 onwards)   

1       58105-1000

Soft Close (2018 onwards)  

1       58105-2000

3 & 4

Bowl Spud & Intake 

1

29048-0000

Elbow & O-ring

5

Clamp

1

18753-0044

6

Hose

1

29035-0001

7

Bowl Installation Hardware

1

18753-0637

7A

Phillips Head Screw**

4

7B

Washer, Starlock**

4

7C

Hex Nut** (two places)

4

7D

Washer, Plastic**

4

7E

Washer Stainless steel**

8

7F

Nut Cap**

4

8

O-Ring Bowl/Seal

1

44101-1000

9

Base Assembly**

1

37004-1000

10

1-1/2" Adaptor, Discharge Port

1

98023-0080

11

Joker Valve* **

1

12

1" Discharge Port**

1

44107-1300

13

Screw**

3

14

Chopper Plate† with Lock Nut

1

37056-1000

15

Macerator Housing †

1

37014-0000

16

Centrifugal Impeller †

1

37006-0000

17

Set Screw †

1

18753-0492

18

O-ring*†

1

43990-0066

19

Sealing Sleeve †

1

37036-1000

20

Screw †

2

91009-0096

21

Screw †

2

91010-0130

22

Washer, Fiber*†

2

35445-0000

23

Wearplate Kit ‡†

1

37018-0000

24

Lock Washer #10, Stainless Kit † 4

25

Screw †

4

91027-0011

26

Gasket*†

1

12558-0000

27

Flexible Impeller*†

1

6303-0003

28

Body †

1

12554-0000

29

Seal & Retainer*†

1

1040-0000

Qty. 

Part 

Key

Description

Req.

Number

30

Slinger †

1

6342-0000

31

Motors:

Motor - 12 Volt †

1

37064-0000

Motor - 24 Volt †

1

37065-0000

32

Adaptor

2

93003-0240

33

Switch & Plate

1

37020-0000

34

Motor Cover †

1

43990-0051

35

Screw Cover (3 each)

1

37003-1000

Service Kit

37040-0000

Motor/Pump Assy. 12V  †

37041-0010

Motor/Pump Assy. 24V  †

37042-0011

*

Parts Supplied with Service Kit 37040-0000.

**  Parts included with base 37004-1000.
‡ Wearplate  #23  includes  Sealing  Sleeve  #19  and  Pump/

Base O-ring #18.

†  Parts included in Motor-Pump Assembly.

OT

H

S

U

P

FLUSH

TR

I

C

CE

L

E

T

O

IL

E

T

8

9

10

11

14

12

13

21

20

4

15

16

17

18

22

23

24

25

26

27

28

29

30

31

32

5

6

3

2

7F

7C

7E

7D

7A

34 

33

B

Elbow

19

1

7B

35

7C

}

www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts

Jabsco Pumps 37010-3092

Содержание 37010-3092

Страница 1: ... provide a separate fresh water tank to supply water to the toilet only DO NOT CONNECT INLET HOSE TO A PRESSURIZED WATER SYSTEM Flood hazard If toilet is installed below the waterline or may be below the waterline at any angle of heel or trim it must be installed with properly positioned vented loops Failure to do so can result in flooding which can cause loss of property and life WARNING CAUTION ...

Страница 2: ...iods of non use toilet and pump may dry out To ease initial start up put about one quart of water in bowl and let stand awhile before initial use DISASSEMBLY Disconnect pumping inlet and discharge hoses Remove four screws Key No 25 pull out complete motor pump and macerator assembly If assembly does not slide out easily push forward and pull back sharply several times to free macerator housing fro...

Страница 3: ...14 0000 16 Centrifugal Impeller 1 37006 0000 17 Set Screw 1 18753 0492 18 O ring 1 43990 0066 19 Sealing Sleeve 1 37036 1000 20 Screw 2 91009 0096 21 Screw 2 91010 0130 22 Washer Fiber 2 35445 0000 23 Wearplate Kit 1 37018 0000 24 Lock Washer 10 Stainless Kit 4 25 Screw 4 91027 0011 26 Gasket 1 12558 0000 27 Flexible Impeller 1 6303 0003 28 Body 1 12554 0000 29 Seal Retainer 1 1040 0000 Qty Part K...

Страница 4: ...diaries 43000 0789 Rev B 43000 0612 Rev D 12 2017 THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO ONE YEAR LIMITED WARRANTY WHICH IS AVAILABLE FOR YOUR INSPECTION UPON REQUEST www ittflowcontrol com Copyright 2010 ITT Corporation Printed in U S A All Rights Reserved Form 43000 0612 Rev A 11 2010 1 Dia 25 4 102 6 152 D Overall Width C G E F 5 16 8 3 1 8 79 B A 10 7 8 12 15 16 5 8 Dia 2 Plac...

Отзывы: