JABSCO 36600-0000 Скачать руководство пользователя страница 2

WIRING DIAGRAM FOR AUTOMATIC
OPERATION

WIRING FOR AC VOLTAGE MODEL:

Use 16 gauge stranded copper wire for lengths up to 100
feet from power source. Connect the grounded,
unswitched conductor (white) to the white motor lead.
Connect the ungrounded switched conductor (black) to
the black motor lead. This conductor should include, at
the power source, a 1.5 amp 125 volt fuse. The green
motor lead must be connected to the AC circuit ground.

MAINTENANCE

WINTER STORAGE:

When possible it is preferred that the complete pump be
removed and stored in a warm dry place. If this is not 
possible the pump must be completely drained, hoses
removed and pump run until all water is expelled.

ELECTRICAL SPECIFICATIONS

Model

Wire Size for Length of Run

Fuse/

Number

Voltage

1-25 feet

25-50 feet

Breaker*

36600-0000

12 Vdc

12 AWG

10 AWG

15 amp

36600-0010

24 Vdc

14 AWG

14 AWG

8 amp

36600-0031

115 Vac

16 AWG

16 AWG

1-1/2 amp

* Customer supplied, not included with pump.

SERVICE

DIAPHRAGM AND CONNECTING ROD 
REPLACEMENT

1.

Turn off power to pump. Remove four tie down bolts.

2.

Lift jack shaft and the attached diaphragm assembly
from pump base.

3.

Remove two diaphragm retainer screws and the
diaphragm retainer.

4.

Remove lock nut. Remove connecting rod and
diaphragm from jack shaft, then unscrew bolt to sep-
arate diaphragm and plates.

5.

Check diaphragm for cuts and cracks. Check rod
assembly bearing for excessive wear. Replace if
badly worn.

6.

Loosely reassemble diaphragm, diaphragm plates,
washer and diaphragm bolt onto connecting rod.
Firmly secure connecting rod to jack shaft with the
lock nut. Secure diaphragm to motor mount with the
diaphragm retainer and two screws.

7.

Tighten connecting rod bolt.

VALVE REPLACEMENT

1.

Turn off power to pump. Remove four tie down bolts.

2.

Expose valves by lifting jack shaft and attached
diaphragm assembly from pump base. Remove and
clean or replace valves.

3.

Install valves, making sure rubber flapper is UP on
intake and DOWN on discharge.

4.

Replace motor-mount-diaphragm assembly and 
fasten evenly to base with the four tie down bolts.

PULSATION DAMPENERS REPLACEMENT

1.

Disconnect power leads from pump and remove
from mount.

2.

Remove nine bottom cap screws and three bottom
plate screws. Remove bottom cap and plate. Pull out
and replace pulsation dampeners.

3.

Replace bottom cap, plate and screws. Tighten
evenly to ensure air and water seals.

4.

Reinstall pump and reconnect power leads.

Automatic Bilge Switch

Model 30295-2000

per instructions

TROUBLESHOOTING

Problems

Causes

Loss of suction to pump.

-Air leak in suction line.
-Bilge pickup not sub-

merged.

-Intake hose kinked or

plugged.

-Fouled intake or discharge

valve.

-Ruptured diaphragm.

Rough or noisy operation.

-Intake or discharge hose

kinked or plugged.

-Pump not mounted firmly.
-Loosened eccentric screw.
-Ruptured or  collapsed

pulsation dampener.

BATTERY

44960-0000

FUSE/

BREAKER

PUMP

MANUAL

OFF

AUTOMATIC