WARNING
EXISTING INSTALLATIONS
• When restoring an existing installation to operation,
open all faucets and follow steps in the
Auto-Alignment section.
ELECTRICAL INSTALLATION TIPS
• Wiring can be shortened as needed or left as-is.
• Be sure to bundle wiring, such as with a zip tie, to
avoid snagging other objects.
If the system fails to operate, check electrical
connections, main fuse or breaker, and indicator light on
front panel of controller. See Troubleshooting Section
for more information.
1
2
4
5
3
NOTE:
Loosen Hose
Clamp and
Rotate Fitting
to Facilitate
Installation
Kit Inventory
Tools Required
Location/Pre-install
• Remove Accumulator Tank (if installed). System may not
operate properly if there is an accumulator tank installed
anywhere in the system.
• Mount the VSD Module as close as possible to the pump
discharge. (Kit is set up to mount directly to pump discharge)
PARTS KEY
1. Water System Hose
2. Pump Elbow Hose
3. Quick-Connect Fitting
4. Universal VSD Unit
5. Wire Nuts
• Screwdriver
• Wire Cutters
• Wire Strippers
• Volt Meter
In addition to basic tools, you may need a towel or rag during installation, as some water may drain
from the hose lines when opened.
Avoid contact with the black metal plate on the rear
of the unit, its temperature may exceed 176°F (80°C).