background image

INSTALLATION

 

MOUNTING

Dual Sensor Max VSD system is self-priming and may be located 
up to 5 feet (1.5m) above the fresh water tank in a dry location.   
Note:  vertical  prime  can  vary  depending  on  the  fluid  viscosity, 
suction  tube  size,  use  of  a  foot  valve,  and  pump  configuration. 
If mounted inside an enclosure, provide adequate ventilation for 
cooling. 
Install four rubber grommets in pump bracket mounting holes. 
The Dual Sensor Max VSD bracket is designed to mount on a 
flat surface with four mounting screws of adequate size. Do not 
mount to a vertical surface. Excessive strain caused by vertical 
mounting may cause failure of the mounting bracket.  Do not 
over tighten mounting screws. Rubber grommets act as shock 
absorbers.  Tighten  mounting  screws  until  rubber  grommets 
are partially compressed. Over-tightening can cause excessive 
noise and vibration in the plumbing system.

PLUMBING

Use flexible hose and plastic fittings of correct pressure rating 
and compatible with the fluid being pumped. Tubing should be 
a minimum of 3/4” (19 mm) inside diameter to provide free flow 
and be secured with stainless steel clamps at each fitting. Do 
not connect pumps directly to rigid pipe. Rigid pipe will amplify 
pump noise and may fatigue and break plastic inlet and outlet 
fittings causing pump to leak. Periodically clean PUMPGUARD 
strainers. Avoid kinks in flexible plumbing. 

WIRING

Consult  the  WIRING  DIAGRAM  for  proper  circuit  connection. 
The  Dual  Sensor  Max  VSD  should  be  wired  to  the  power  
supply  through  a  switch  rated  for  25  amps.  An  inline  fuse  is  
factory  installed  in  each  pump  to  provide  over  current  
protection to each pump. The pump circuit should not include 
any  other  electical  loads.  Red  wire  is  positive.  Black  wire  is 
negative.  Turn  the  system  off  when  not  in  use  for  extended 
periods or when supply tank is empty. 
IMPORTANT    VSD electronics require that a battery be 

installed in the DC power supply when using an AC to DC 

converter or battery charging system. Electrical noise from 

the  converter  or  battery  charging  system  can  interfere  with 
proper operation of the VSD circuit unless a battery is present 
in the DC power supply as shown in the WIRING DIAGRAM. 
IMPORTANT  Polarity of electrical connections is very impor-

tant.  Insure  that  the  RED  (+)  motor  lead  is  connected  to  a 
fused positive DC circuit. The BLACK (-) motor lead must be 
connected to the negative DC circuit. In the event the polarity 
is reversed on the VSD pump, the fuse found in the ‘EMI Filter 
Box’ built into the VSD power wire leads must be replaced. 
IMPORTANT    This  system  should  be  installed  by  a  qualified 

electrician  or  someone  familiar  with  applicable  electrical  and 
safety standards.
Use  wire  size  according  to  the  chart  below.  Total  wire  length 
refers to the distance from the DC power source to the pump 
and back to the power source. This chart provides for a maxi-
mum 3% voltage drop. 

WIRE SIZE TABLE

  Total wire  

0-20 ft 

20-30 ft 

30-40 ft 

40-60 ft 

 

length 

(0-6 m) 

(6-9 m) 

(9-12 m) 

(12-18 m)

 

Wire 

#10 AWG 

#8 AWG 

#6 AWG 

#4 AWG 

 

Size 

(6 mm2) 

(10 mm2) 

(16 mm2) 

(25 mm2)

 Motor case will get hot during extended 

operation. Prolonged contact with skin 

may cause a burn.

PRE-OPERATION CHECKS

The supply tank should be at least half full prior to initial opera-
tion. Insure all plumbing connections are secure. Insure flexible 
tubing is not kinked. Insure all electrical connections are secure 
and  in  accordance  with  the  WIRING  DIAGRAM.  Open  all  hot 
and  cold  water  faucets  and  fixtures.  Insure  that  water  heater 
circuit is off.

WARNING

!

Explosion hazard.  Do not pump gasoline, solvents, 

thinners or other flammable liquids.  To do so can 

cause an explosion resulting in injury or death.

FLEXIBLE

HOSE

RIGID

PIPE

WARNING

!

Fire hazard.  Wiring must comply with 

applicable electrical standards and include

 

a properly sized fuse or circuit breaker.

.  

Improper wiring can cause a fire resulting

 

in injury or death.

Tank

Vent

Water

Tank

Tank

Fill

Faucet

Faucet

Shower

Dual Sensor

Max VSD

Check

Valve

Water

Heater

Hot Water

Line

Red (+)

(+)

On/Off

Switch

EMI

Filter Box

DC Battery

(–)

Black (–)

Inline

Fuse

TYPICAL PLUMBING SYSTEM

WIRING DIAGRAM

 When using a power supply or 

converter, a battery must be in the 

circuit for proper operation.

NOTICE