Motor case will get hot. Prolonged 

contact during operation may cause a burn.

City Water Intake

Pressure Regulator

Water Pressure 

Pump

Pumpgard™

Strainer

Water

Supply Tank

Tank

Fill Vent

Sink

Sink

Hot Water

Line

Cold Water

Line

Water

Heater

Check

Valve

Shower

Accumulator

Tank

INSTALLATION

MOUNTING

The PAR-MAX pumps are self-priming and may be locat-
ed above or below the fresh water tank in a dry location.
To vertically mount these units, it is best to do so with the
motor on top. This will prevent water dripping on motor
in the event of a leak. Place pump on a solid surface
and secure with four mounting screws (not included)
being careful not to compress the rubber grommets
which act as shock absorbers.

PLUMBING

Select two of the port adaptors supplied to match your
plumbing system. Flexible potable water hose or PEX
tubing is recommended instead of rigid piping at
pump. 
If you choose to use rigid piping, provide a short
length of hose between pipe and the pump to avoid
noise and vibration. Use clamps at both ends of hose to
prevent air leaks into the water line. NOTE: Intake hose
must be minimum 1/2" (13 mm) ID reinforced hose. Main
distribution line from pump outlet should also be 1/2" (13
mm) ID with branch and individual supply lines to outlets
no smaller than 3/8" (10 mm). A Jabsco “Pumpgard” in
line strainer should be installed between pump and tank
to keep debris out of pump and system. Fresh water tank
must be vented. Avoid any kinks or fittings which could
cause excessive restrictions. Remember to periodically
clean faucet and “Pumpgard” screens.

WIRING

In an easily accessible location, install a switch (Jabsco
44960-Series) to control electricity to the pump. Turn the
pump off when not used for extended periods or when
the tank is empty.

The electrical circuit should be protected with an over-
current protection device in the positive lead. See chart
for proper size. The pump circuit should not include any
other electrical loads. The free lead at the pressure

switch is positive. Black wire from the motor is negative.

Select wire size from chart below. Use total length of wire
from the battery to pump and return. Chart allows for 3%
voltage drop. If in doubt, use next larger wire size.

If you are not familiar with applicable electrical stan-
dards, have the unit installed by a qualified electrician.

After installation, check the voltage at the pump motor.
Voltage should be checked when pump is operating. Full
voltage must be available at the pump motor at all times.

OPERATION

1. Check level of water in tank.
2. Open all faucets hot and cold.
3. Switch on power to pump and wait for hot water tank

and water lines to fill.

4. Close each faucet as flow becomes steady and free of

air (close cold water faucet first). Pump should shut off
soon after closing last faucet.

5. Pump is now ready for automatic operations. It will

start when faucet is opened and stop when faucet is
closed.

6. If pump will be inoperative for a considerable length of

time, turn off circuit to pump and bleed system by
opening faucet.

QUICK EASY INSTALLATION

VERSATILE SNAP-IN PORTS

Total length

in feet

12 Volt

24 Volt

0-20

(0-6 m)

#14 AWG

(2.5 mm

2

)

#16 AWG

(1.5 mm

2

)

20-35

(6-11 m)

#12 AWG

(4 mm

2

)

#14 AWG

(2.5 mm

2

)

35-55

(11-17 m)

#10 AWG

(6 mm

2

)

#12 AWG

(4 mm

2

)

WARNING!

Explosion hazard. Do not pump
gasoline, solvents, thinners or other
flammable liquids. To do so can
cause an explosion resulting in injury
or death.

WARNING

!

Fire hazard.  Wiring must comply with 
applicable electrical standards and 
include a properly sized fuse or circuit 
breaker.  Improper wiring can cause a 
fire resulting in injury or death.