JABSCO 30520-4 Series Скачать руководство пользователя страница 2

3. Remove mechanical seal by inserting two screwdrivers

behind  seal  collar,  and  gently  lever  collar  and  seal

assembly forward on shaft.  Use extreme care not to

mar shaft surface.  Remove seal seat and rubber cup

from recess in wearplate.

4. Remove  the  four  screws  holding  the  adpater  to  the

motor and remove the adapter.

5. The  stub  shaft  is  held  in  place  with  set  screws  and

Loctite*  RC/680  retaining  ring  compound.  Extreme

care must be taken not to damage the motor shaft and

bearings  when  removing  the  stub  shaft.    Heat  shaft

joint area to facilitate disassembly of set screws and

stub shaft from motor shaft.  DO NOT EXCEED 300°F

when  heating  joint  area.    Once  joint  area  has  been

heated, remove set screws and slide stub shaft from

motor shaft.

ASSEMBLY

1. Liberally apply Loctite RC/680 retaining compound to

the motor shaft and slide the stub shaft on, positioning

the base of the stub shaft 0.37" from the bolt mounting

surface  of  the  motor  and  two  of  the  four  set  screw

holes over the keyway in the motor shaft.  For clarifi-

cation refer to Figure 1 below.  Loctite aids in preventing

fretting and subsequent shaft failure.  Apply Loctite to

the two dog point (flat point) set screws, position in the

set screw holes aligned with the keyway of the motor

shaft and torque to 55 - 60 in. lbs.  Apply Loctite to the

two cup point set screws and torque to 85 - 90 in. lbs.

Wipe off excess Loctite.

2. Replace the adapter on the motor and torque the four

mounting screws to 20 ft. lbs.

3. Replace mechanical seal by sliding spacer onto shaft

up  to  locating  shoulder,  then  smear  shaft  with  light

lubricating oil.  Push on seal gently until it engages with

spacer.  Fit rubber cup and seal seat into wearplate.  

4. Insert impeller in pump body, fit O-ring in each end of

the pump body.

5. Slide wearplate and body assembly over shaft, posi-

tion wearplate in housing.  Fit body to pedestal with

screws.  Torque screws to 60 in. lbs.

NOTE:  A gap should be maintained between bearing

housing and body. DO NOT overtighten screws.

6. Fit end cover and end cover screws.  Torque screws to

60 in. lbs.

7. Changing Pump Rotation (looking at end cover):

a. Clockwise Rotation: Insert impeller into pump body

with blades bending counterclockwise.

b. Counterclockwise Rotation: Insert impeller into

pump body with blades bending clockwise.

OPERATING INSTRUCTIONS

(Cont)

factor of one. Due to high bearing loads, motor should

be ball bearing equipped with the front bearing locked

against  axial  movement.  Motor  should  be  capacitor

start and foot mounted.

3. SPEEDS – 100 RPM to the maximum shown in the

performance curves.  Consult the factory for operation

at speeds above these shown.  For longer pump life,

operate at lowest possible speeds. Lower speeds are

required  for  viscous  liquids.    Consult  the  factory  for

proper speeds and horsepower requirements.

4. SELF-PRIMING – Primes at low or high speeds.  For

vertical dry suction lift of 10 feet, a minimum of 860

RPM is required. Pump will produce suction lift up to

22 feet when wet. BE SURE SUCTION LINES ARE

AIRTIGHT OR PUMP WILL NOT SELF-PRIME.

5. DISCHARGE – When transferring liquids further than

25 feet, use one size larger discharge line than dis-

charge port size.

6. RUNNING DRY – Unit depends on liquid pumped for

lubrication. DO NOT RUN DRY for more than 30 sec-

onds. Lack of liquid will damage the impeller and seal.

7. CHEMICAL COMPATIBILITY – Consult the Chemical

Resistance  Guide  in  the  JABSCO  Industrial  Pump

Catalog (available upon request from ITT Jabsco) or

factory  for  proper  body  materials  and  impeller

compounds. If corrosive fluids are handled, pump life

will be prolonged if pump is flushed with a neutralizing

solution  after  each  use  or  after  each  work  day.  A

Tungsten  Carbide  Seal  variation  is  available  for

pumping  liquids  that  contain  abrasives  or  are  highly

corrosive.

8. PRESSURES – Consult Performance Curves for maxi-

mum recommended pressures for pumps in continuous

operation. If pressures exceed those shown, consult

the factory.

9. TEMPERATURES – The operating temperature limits

of the pump depend on the impeller compound. The

following ranges apply: Neoprene - 45° to 180° F (7° to

82° C), Nitrile - 50° to 180° F (10° to 82° C), Viton - 60°

to 180°F (15° to 82°C), EPDM - 45° to 185°F (7° to

85°C).

10. IMPELLER TORQUE – The torque required to initiate

rotation of a new impeller in a dry pump body is:

Standard Pressure Impeller (14282-Series):

Forward = 4.8 pounds force - feet

Reverse = 11.2 pounds force - feet

These values may vary slightly due to impeller com-

pounding, blade set, and body material of construction.

Consult factory for more information.

11. SPARE PARTS – To avoid costly shutdowns, keep a

spare JABSCO impeller, seal and O-ring set on hand.

SERVICE INSTRUCTIONS

DISASSEMBLY

1. Remove  the  four  end  cover  screws.  Remove  end

cover and O-ring.

2. Remove  the  four  screws  holding  the  body  to  the

adapter flange.  Slide body, complete with impeller and

wearplate, from adapter and shaft.

Loctite* is a trademark of the Loctite Corporation.