DIMENSIONAL DRAWING
Inches (millimeters)
GERMANY
Jabsco GmbH
Oststrasse 28
22844 Norderstedt
Tel: +49-40-53 53 73 -0
Fax: +49-40-53 53 73 -11
UNITED KINGDOM
Jabsco
Bingley Road, Hoddesdon
Hertfordshire EN11 OBU
Tel: +44 (0) 1992 450145
Fax: +44 (0) 1992 467132
CANADA
Fluid Products Canada
55 Royal Road
Guelph, Ontario N1H 1T1
Tel: (519) 821-1900
Fax: (519) 821-2569
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222
Tel: 045-4758906
Fax: 045-475-8908
U.S.A.
Jabsco
1485 Dale Way, P.O. Box 2158
Costa Mesa, CA 92628-2158
Tel: (714) 545-8251
Fax: (714) 957-0609
© Copyright 2000, ITT Industries
Printed in U.S.A.
All Rights Reserved
Form: 43000-0154 Rev. 7/2000
THE PRODUCTS DESCRIBED HEREIN
ARE SUBJECT TO THE JABSCO ONE YEAR
LIMITED WARRANTY, WHICH IS AVAILABLE
FOR YOUR INSPECTION UPON REQUEST.
PSI
kg/cm
2
TOTAL HEAD
500 RPM
870 RPM
1160 RPM
Feet
of
Water
Meters
of
Water
1450 RPM
1750 RPM
2100 RPM
2450 RPM
4.3
8.7
17.3
26.0
30.3
GPM l/min
HP
23
22
17
—
—
87
83
64
—
—
1/2
1/2
1/2
—
—
GPM l/min
HP
40
37
30
22
—
151
140
114
83
—
1
1
1
1-1/2
—
GPM l/min
HP
54
50
43
34
—
204
189
163
129
—
1
1
1-1/2
1-1/2
—
GPM l/min
HP
70
66
58
48
41
265
250
220
182
155
1-1/2
1-1/2
1-1/2
2
2
GPM l/min HP
83
79
71
61
55
314
299
269
231
208
2
2
3
3
3
GPM
l/min
HP
95
91
82
70
62
360
344
310
265
235
3
3
3
5
5
GPM
l/min
HP
108
104
93
81
73
409
394
352
307
276
3
3
5
5
5
0,3
0,6
1,2
1,8
2,1
3,0
6,1
12,2
18,3
21,3
10
20
40
60
70
MODEL 18330-SERIES 2" PORTS HEAD CAPACITY TABLE
R
OT
ATIO
N
8 "
( 2 0 3 )
4 "
( 1 0 2 )
1
7
/
8
"
( 4 8 )
3
3
/
4
"
( 9 5 )
4
1
/
2
"
( 1 1 4 )
7
9
/
16
"
( 1 9 2 )
7
7
/
8
"
( 2 0 0 )
1 1
1
/
8
"
( 2 8 3 )
2
3
/
16
"
( 5 6 )
3
3
/
16
"
( 8 1 )
1
1
/
2
"
( 3 8 )
5
/
8
"
( 1 5 . 9 )
2
1
/
2
"
( 6 3 , 5 )
6
1
/
4
"
( 1 5 9 )
7 "
( 1 7 8 )
4
1
/
8
"
( 1 0 5 )
2 " N P T
13
/
32
" ( 1 0 ) D I A
4 H O L E S
1
5
/
8
"
( 4 1 )
O U T L E T
P O R T
O U T L E T
P O R T
NOTE:
Progressively longer life may be expected as operating pressures and speeds are reduced. Factory Application Engineering assistance
suggested for operation in light shaded area and recommended for heavy shaded area. Table shows approximate Head-Flow for new pump in
U.S. gallons per minute.