![JABSCO 18330 Series Скачать руководство пользователя страница 1](http://html.mh-extra.com/html/jabsco/18330-series/18330-series_quick-start-manual_628220001.webp)
SELF-PRIMING PUMPS
Electro-Magnetic Clutch Units
FEATURES
Body:
Bronze
I m p e l l e r :
Jabsco Nitrile Compound
S h a f t :
Brass
Po r t s :
2" NPT
S e a l :
Carbon-Ceramic Face Type
Bearings:
Sealed Ball Bearings
Shipping Weight: 29 lb (13,2 kg)
Model 18330-Series
Model 18330-Series
STANDARD MODELS
Model
Voltage
Belt(s)
18330-0000
12 Vdc
2-A
18330-0040
12 Vdc
1-B
18330-0001
24 Vdc
2-A
18330-0041
24 Vdc
1-B
APPLICATIONS
MARINE:
Engine cooling, Pumping bilges, Washdowns,
Circulating water in bait tanks, Utility dockside pump.
INDUSTRIAL:
Circulating and transferring, Velocity-
mixing, Return spill, Sump drainage, Chemicals, Pharma-
ceuticals, Soap, Liquors, Ink, Dyes, Alcohol, Tanning
Liquors, Glycerine, Brine, etc.
FARMING:
Pumping water for stock, Pumping water from
shallow wells and cisterns.
PUBLIC UTILITIES AND MUNICIPALITIES:
Under
the hood mounting on service trucks for dewatering and
draining meter boxes, manholes, excavations, and truck
installation under hood for emergency pumping.
INSTALLATION
Pump may be mounted in any position. Intake and discharge
ports are determined by the direction of shaft rotation (refer
to dimensional drawing). Before installing, energize clutch
and turn pump shaft in direction of shaft rotation. Drive
pump with two "A" size belts. Avoid dry-running by using
Vacuum Switch Model 4732-0000 for automatic shut-off.
NOTE: MODEL 18330-SERIES IS INTERCHANGEABLE
WITH EARLIER PUMP MODEL 10680-SERIES: BASE
MOUNTING DIMENSIONS, HEIGHT ABOVE BASE TO
SHAFT, AND HEIGHT ABOVE BASE TO PORT CENTER-
LINE ARE THE SAME.
Injury hazard. Exposed pulleys and belts can
cause injury. Install shield around pulleys and
belts. Stay clear while machinery is operating.
WARNING
!
WIRING
Connect wires as shown for manual on-off operation.
Install proper size fuse (see Electrical Specification Chart)
in positive lead ahead of switch and as close to power
source as possible. For remote control or automatic shutoff
operation, see data sheet on Model 4732-0000 Vacuum
Switch Kit (Form 43000-0024). For complete wiring
instructions see diagram on page 2.
CLUTCH ELECTRICAL SPECIFICATIONS
VOLTAGE
AMP DRAW
FUSE SIZE
12
4
7
24
2
4
OPERATION
Pump will self-prime at low or high speeds. Make sure that all
connections are airtight. 12 Volt models are equipped with
mechanical clutch engagement screws in case of electrical failure.
To mechanically engage clutch, loosen locking nuts, tighten allen
head screws and retighten locking nuts. Reverse procedure to
disengage clutch. If the mechanical engagement feature is not
desired, the screws may be removed. DO NOT RUN PUMP DRY
FOR MORE THAN 30 SECONDS. LACK OF WATER FLOW MAY
DAMAGE IMPELLER. To drain pump, loosen end cover screws.
See Head Capacity Table for head pressures and flow. To avoid
costly shutdowns, keep a Jabsco Service Kit on hand.