The UC-261 wireless indoor siren
The UC-261 indoor siren communicates wirelessly with the
control panel (two way communication). It can be used as a
wireless indoor siren and at the same time as a melody doorbell
or as a chime indicator. The UC-261 is compatible with Jablotron
wireless control panels (JA-63 and JA-65), JA-60 wireless
detectors and RC-4x, RC-22 and RC-28 remote controls.
Several triggering devices can be used simultaneously and
different melodies can be assigned to each device. Two different
sound levels can be selected. The UC-261 can also provide
entrance and exit delay chirps when used with a control panel.
In addition, if the UC-261 is disconnected from the power it will
send an error report to the control panel.
Specification
Power supply
230 V, 50 Hz
Power consumption
1 W
Acoustics
8 melodies and/or 100 dB/m alarm siren
Input wireless devices
max. 8 remote controls or detectors
1 control panel, JA-63 or JA-65
Class
II according to EN60950
Working frequency
433.92 MHz
Environmental conditions
indoors –10 to +40°C
Safety standards
IP40 according to EN 60529, IEC 529
Jablotron Ltd. hereby declares that the UC-261
is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC.
The original of the conformity assessment can be found at
www.jablotron.com
, Technical Support section.
Installation
The UC-261 is powered directly from a power outlet. The
device should not be installed close to any metal structures or
other objects obstructing radio signal transmissions.
Enrolling of wireless devices:
1.
To enroll the JA-63 or 65 control panel
switch the control
panel to enrollment mode.
2.
While pressing and holding a button on the UC-261,
plug it into the outlet
to transmit the enrollment signal.
3.
Release the button
when
you hear two beeps. The flashing
button indicates that it is in programming mode.
Consequently the UC-261 will be enrolled to siren position “A”.
4. If another wireless siren has already been enrolled to the
control panel, then it is necessary to enroll the UC-261 to a
detector position by entering
000000
in control panel
enrollment mode before plugging the UC-261 into the outlet
(see also the control panel manual).
5. Exit enrollment mode of the control panel by pressing N.
6. If it is necessary to enroll other devices to the UC-261, see
following procedure (points 7 to 9). Or
exit programming
mode
by briefly pressing the button on the UC-261.
NOTE:
•
If position “A” is occupied and you plug the UC-261
into the outlet in control panel enrollment mode, then
the former item (e.g. JA-60A) will be deleted.
•
Only one control panel can be enrolled to the UC-261 but
more UC-261 units can be enrolled to one control panel.