UC-261 wireless indoor siren 

1 / 2 

MFI52702 

The UC-261 wireless indoor siren

 

 

The UC-261 indoor siren communicates wirelessly with the 

control panel (two way communication). It can be used as a 
wireless indoor siren and at the same time as a melody doorbell 
or as a chime indicator. The UC-261 is compatible with Jablotron 
wireless control panels (JA-63 and JA-65), JA-60 wireless 
detectors and RC-4x, RC-22 and RC-28 remote controls. 
Several triggering devices can be used simultaneously and 
different melodies can be assigned to each device. Two different 
sound levels can be selected. The UC-261 can also provide 
entrance and exit delay chirps when used with a control panel. 
In addition, if the UC-261 is disconnected from the power it will 
send an error report to the control panel. 

 

Specification 

 

Power supply 

230 V, 50 Hz 

Power consumption 

1 W 

Acoustics 

8 melodies and/or 100 dB/m alarm siren 

Input wireless devices  

max. 8 remote controls or detectors 

 

1 control panel, JA-63 or JA-65 

Class 

II according to EN60950 

Working frequency 

433.92 MHz 

Environmental conditions 

indoors –10 to +40°C 

Safety standards 

IP40 according to EN 60529, IEC 529 

Jablotron Ltd. hereby declares that the UC-261

 

is in 

compliance with the essential requirements and other 
relevant provisions of Directive 1999/5/EC. 

The original of the conformity assessment can be found at 

www.jablotron.com

, Technical Support section.

 

 
 

 

Installation 

The UC-261 is powered directly from a power outlet. The 

device should not be installed close to any metal structures or 
other objects obstructing radio signal transmissions.  

 

Enrolling of wireless devices:

 

 

1. 

To enroll the JA-63 or 65 control panel 

switch the control 

panel to enrollment mode. 

2. 

While pressing and holding a button on the UC-261, 
plug it into the outlet 

to transmit the enrollment signal.  

3. 

Release the button 

when

 

you hear two beeps. The flashing 

button indicates that it is in programming mode. 

Consequently the UC-261 will be enrolled to siren position “A”. 

 

4. If another wireless siren has already been enrolled to the 

control panel, then it is necessary to enroll the UC-261 to a 
detector position by entering 

000000 

in control panel 

enrollment mode before plugging the UC-261 into the outlet 
(see also the control panel manual). 

5. Exit enrollment mode of the control panel by pressing N. 
6. If it is necessary to enroll other devices to the UC-261, see 

following procedure (points 7 to 9). Or

 exit programming 

mode

 by briefly pressing the button on the UC-261. 

NOTE:  

 

If position “A” is occupied and you plug the UC-261 
into the outlet in control panel enrollment mode, then 
the former item (e.g. JA-60A) will be deleted.  

  Only one control panel can be enrolled to the UC-261 but 

more UC-261 units can be enrolled to one control panel. 

 
 
 
 
 
 
 