background image

Range of temperatures settings. 

Settings 

item 

Range 

Factory 

settings 

Description 

HYst 

0.1°C to 1°C 

0.2°C 

Hysteresis 

t Lo 

+ 6°C to + 40°C* 

6°C 

Lower limit of regulated 
temperature 

t Hi 

+ 6°C to + 40°C* 

40°C 

Upper limit of regulated 
temperature 

AL Lo 

– 9°C to + 20°C 

3°C 

Low temperature alarm 
report 

AL Hi 

+ 30°C to + 70°C 

60°C 

High temperature alarm 
report 

* The ranges of 

t Lo 

and 

t Hi can´t overlap each other

 

  Showing the pre-set temperature 

The thermostat always shows the  current  room temperature in the normal 

mode.  Briefly  pressing the knob will show the temperature which has been 
set for this time. The pre-set temperature flashes 3s then it shows the current 
temperature again. 

  Replacing the batteries 

When the thermostat starts to  indicate  the  Low  Batt  symbol  (

)  or stops 

working completely, replace the batteries for new ones. A Low battery report 
is sent to the receiver.  

Note:  We  strongly  recommend  only  using  alkaline  batteries, 

type AA 1.5V. 

  Integration into the OASiS system 

The thermostat can be 

enrolled to a control panel as a detector

. If the 

temperature decreases below 

AL Lo

 a 

panic alarm

 will be triggered = frost 

threat (heating failure). 

If the temperature exceeds 

AL Hi

 then a 

fire alarm

 will be triggered. 

An  AC-82 receiving unit (AC-82) has two output relays (X and Y). 

Thermostats can be enrolled separately to each relay in order to 

control two 

independent heating circuits

.  

To operate a heating system the OASIS control panel

  can also be 

enrolled (sequence 299) to the same relay of the receiving unit (AC-82) as 
the thermostat is enrolled to. A thermostat enrolled to the 

X

  relay 

can be 

operated via the PGX programmable output

, and a thermostat enrolled to 

the 

Y

  relay operated via 

PGY

. If the programmable 

output of the control 

panel is switched on,

  the thermostat maintains the programmed 

temperature. If the control panel´s output is 

switched off

 the thermostat only 

triggers heating if the temperature drops 

below Stby.

  

To operate the heating, RC-80 or RC-88 remote controls can also be 

enrolled to receiving unit (AC-82). The heating can be switched on by remote 
controls to heat th the desired temperature and also 

switched off where it 

only heats when the temperature is below Stby

To disable heating when windows are open

  JA-81M or JA-82M 

detectors

  can also be enrolled to the same relay as the thermostat is 

enrolled to. If the windows are closed it 

heats

 to the desired temperature and 

if windows are open it 

heats only when the temperature is below Stby

Up to 8 thermostats

  can be enrolled to a single relay. If at least on the 

thermostat transmits a heat command then the relay will be switched on. 

 

Technical specifications 

Power: 

2x AA LR6 1.5 V / 2.4 Ah alkaline batteries 

Lifetime of batteries: 

typically 1 year 

Regulation range: 

+6 °C to +40 °C 

Temperature regulation sensitivity: 

adjustable: 0.1- 1 °C 

Alarm when temperature drops below ALLo: 

-9 °C to +20 °C   

Alarm when temperature exceeds ALHi: 

 +30 °C to +70 °C 

Communication band: 

868.5 MHz, Oasis protocol 

RF range: 

up to 100 m (open area) 

Operational temperature: 

-10 °C to + 70 °C (no condensation) 

Dimensions: 

66 x 90 x 22 mm 

Complies with: 

ETSI EN 300220, EN50130-4, EN55022, EN 60950-1 

Can be operated according to

 

ERC REC 70-03

 

 

JABLOTRON ALARMS a.s. hereby declares that the TP-82N 
module is in compliance with the essential requirements and other 
relevant  provisions of Directive 1999/5/EC  and 2011/65/EU.  The 
original of the conformity assessment can be found at 

www.jablotron.com

 - Technical Support section

 

 

Note:

 Although this product does not contain any harmful materials 

we suggest you return the product to the dealer or directly to the 
producer after use. For more detailed information visit 

www.jablotron.com

.

 

 

TP-82N wireless indoor thermostat 

2 / 2 

MKL51106 

Отзывы: