Range of temperatures settings.
Settings
item
Range
Factory
settings
Description
HYst
0.1°C to 1°C
0.2°C
Hysteresis
t Lo
+ 6°C to + 40°C*
6°C
Lower limit of regulated
temperature
t Hi
+ 6°C to + 40°C*
40°C
Upper limit of regulated
temperature
AL Lo
– 9°C to + 20°C
3°C
Low temperature alarm
report
AL Hi
+ 30°C to + 70°C
60°C
High temperature alarm
report
* The ranges of
t Lo
and
t Hi can´t overlap each other
.
Showing the pre-set temperature
The thermostat always shows the current room temperature in the normal
mode. Briefly pressing the knob will show the temperature which has been
set for this time. The pre-set temperature flashes 3s then it shows the current
temperature again.
Replacing the batteries
When the thermostat starts to indicate the Low Batt symbol (
) or stops
working completely, replace the batteries for new ones. A Low battery report
is sent to the receiver.
Note: We strongly recommend only using alkaline batteries,
type AA 1.5V.
Integration into the OASiS system
The thermostat can be
enrolled to a control panel as a detector
. If the
temperature decreases below
AL Lo
a
panic alarm
will be triggered = frost
threat (heating failure).
If the temperature exceeds
AL Hi
then a
fire alarm
will be triggered.
An AC-82 receiving unit (AC-82) has two output relays (X and Y).
Thermostats can be enrolled separately to each relay in order to
control two
independent heating circuits
.
To operate a heating system the OASIS control panel
can also be
enrolled (sequence 299) to the same relay of the receiving unit (AC-82) as
the thermostat is enrolled to. A thermostat enrolled to the
X
relay
can be
operated via the PGX programmable output
, and a thermostat enrolled to
the
Y
relay operated via
PGY
. If the programmable
output of the control
panel is switched on,
the thermostat maintains the programmed
temperature. If the control panel´s output is
switched off
the thermostat only
triggers heating if the temperature drops
below Stby.
To operate the heating, RC-80 or RC-88 remote controls can also be
enrolled to receiving unit (AC-82). The heating can be switched on by remote
controls to heat th the desired temperature and also
switched off where it
only heats when the temperature is below Stby
.
To disable heating when windows are open
JA-81M or JA-82M
detectors
can also be enrolled to the same relay as the thermostat is
enrolled to. If the windows are closed it
heats
to the desired temperature and
if windows are open it
heats only when the temperature is below Stby
.
Up to 8 thermostats
can be enrolled to a single relay. If at least on the
thermostat transmits a heat command then the relay will be switched on.
Technical specifications
Power:
2x AA LR6 1.5 V / 2.4 Ah alkaline batteries
Lifetime of batteries:
typically 1 year
Regulation range:
+6 °C to +40 °C
Temperature regulation sensitivity:
adjustable: 0.1- 1 °C
Alarm when temperature drops below ALLo:
-9 °C to +20 °C
Alarm when temperature exceeds ALHi:
+30 °C to +70 °C
Communication band:
868.5 MHz, Oasis protocol
RF range:
up to 100 m (open area)
Operational temperature:
-10 °C to + 70 °C (no condensation)
Dimensions:
66 x 90 x 22 mm
Complies with:
ETSI EN 300220, EN50130-4, EN55022, EN 60950-1
Can be operated according to
ERC REC 70-03
JABLOTRON ALARMS a.s. hereby declares that the TP-82N
module is in compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC and 2011/65/EU. The
original of the conformity assessment can be found at
- Technical Support section
Note:
Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use. For more detailed information visit
TP-82N wireless indoor thermostat
2 / 2
MKL51106