7.  Monitoring station data sending 

Function of the TD-101 including the Monitoring Station (MS) communication is demonstrated in the 

diagram on page 9. Data is sent to the monitoring station before voice & Pager messages are sent (if 
these messages are used). All parameters of the MS communication should be programmed in 
cooperation with your monitoring service provider. Programming of the data for the MS is only possible 
in the Installer mode.  

If you do not use the dialer to send data to a monitoring station, do not program anything in this 

section.  

 

7.1. Opening of Installer Mode for monitoring station data programming 

To enter Installer level

 

from Standby, 

enter Installer code IC press

 

B

 

and enter Installer Code 

IC again.

 Factory default IC is 1010 so when you open the Installer mode for the first time, enter 

 

B

 

. The installer level is indicated by the yellow LED. 

All parameters are programmed in the following sequences. If the first key of the sequence is 

entered, the red LED will start to flash. When the sequence is completely entered, the red LED will 
turn off (data will be stored). A started sequence entering can also be terminated by pressing the

 

E

key at any time. 

After all programming is finished, the Installer mode must be exited by pressing the

 

E

key (all the 

LEDs will turn off). The dialer can not be activated in the Installer level ! 

 
 

7.2. Entering telephone numbers of the Monitoring Station 

Telephone numbers can be programmed in the Installer mode (the yellow LED is ON - see 7.1.), 

entering:  

 

DDDD

 ... 

D

 

M

E

 

where: 

D

 

is a telephone number, keys 

 to  

 or 

B

 (i.e. pause). Pause can not be on the first 

position, keys 

 and  

 can also be programmed in tone dialing mode. Each telephone 

number can have up to 16 digits.  

E

is the tel. number memory 

7

 = main tel. number (

Mem7

), 

8

 = alternate tel. number (

Mem8

)

The alternate number is only called  if the main number is busy.  

 

Example: The main telephone number of the monitoring station will be  811 777 : 

 

M

 

7.3. Deleting of Monitoring Station telephone numbers 

Telephone numbers for MS can be deleted in the installer mode (the yellow LED is ON - see 7.1.), 

entering:  

 

B

 

M

%

where:  

%

is the memory number 

7

 or 

8

 which will be erased. If a number is erased,  the corresponding 

dialing will not be performed.  

Note: If both numbers for MS are erased, there will be no communication to the monitoring 
station

 

 

Example: Spare MS telephone number will be erased : 

B

 

M

 

 

   If Stop with 

E

key is enabled, the TD-101 action can be stopped only if no input is triggered. The dialer 

action is terminated a few seconds after the 

E

key is pressed.  

If Stop is disabled, the communication can not be stopped before its end. 

 

Example: The STOP will be disabled : 

F

 

8.11. Emergency triggering with 

F

key

 

Emergency trigger key can be enabled or disabled in the installer mode (the yellow LED is ON - see 

8.1.), entering: 

 

F

D

 

where: 

D

=

0

  emergency trigger disabled 

D

=

1

  emergency trigger enabled      

(factory default setting)

 

If you use the 

F

key as an emergency button, you can mark the key with an adhesive label which 

is included.  

Note: The above setting does not have any effect to the remote control trigger of TD-101W model.  

 

Example: Emergency trigger will be disabled : 

F

 

 

8.12. Changing of the Installer Code  

To avoid non authorized access to the installer mode, change the Installer Code for a new one. The 

code can be changed in the installer mode (the yellow LED is ON - see 8.1.), entering:  

 

M

DDDDDDDD

 

where : 

DDDD

 is the new installer code (four digits). The new code must be entered twice to be changed 

(protection of accidental change). The original factory default setting of the Installer Code is 
1010. 

 

Example : The user code will be changed for code 3112 : 

M

 

  

8.13. Duration of Pause in Pager dialing  

Duration of the pause which is generated with the 

F

key in pager number programming can be 

selected in the installer mode (the yellow LED is ON - see 8.1.) entering.  

 

F F 

D

 

where : 

D

=

0

  pause = 5 seconds (factory default) 

D

=1  pause = 10 seconds 

 

Example: 10 seconds Pause will be selected: 

 

F F

 

 
 

 

Содержание TD-101

Страница 1: ...Pod Skalkou 33 466 01 Jablonec nad Nisou Czech Republic E mail export jablotron cz http www jablotron cz...

Страница 2: ...1 7 5 Account number programming 11 7 6 Reporting codes programming 11 7 7 Testing the Monitoring Station communication 12 8 Optional functions and parameters programming 12 8 1 Opening of Installer M...

Страница 3: ...factory settings when necessary The autodialer takes priority on your telephone line When triggered it will switch all other devices phone fax PABX off line By checking signals on the line dial busy...

Страница 4: ...urrent switching off There are many possibilities on how to connect the trigger inputs see examples on page 20 Consider that the dialer reacts only to signals with a duration of 0 1sec or longer Each...

Страница 5: ...rm system 20 seconds siren alarm in the system N C or NO contact typical for use with monitoring station trigger selectable 11 2 Use of the dialer only for emergency dialing old or ill people Connect...

Страница 6: ...call a mobile phone To program telephone numbers enter DDDD D ME where D is a telephone number keys to or B i e pause Pause can not be in the first position Keys and can also be programmed in tone dia...

Страница 7: ...with your PAGING provider 6 5 Deleting telephone numbers Telephone numbers for voice pager messages can be deleted in user mode the green LED is ON see 6 1 entering B ME where E is the memory number...

Страница 8: ...ble you can hear tel line signals and voice messages from the built in speaker Example Voice message no 1 will be sent to tel number Mem2 FM 6 9 Changing of the User Code To avoid non authorized acces...

Страница 9: ...beep Check also if the voice messages are recorded and that the telephone numbers are stored in corresponding memories see chapter 6 It is impossible to enter the user or installer mode it can be ente...

Страница 10: ...lled if the main number is busy Example The main telephone number of the monitoring station will be 811 777 M 7 3 Deleting of Monitoring Station telephone numbers Telephone numbers for MS can be delet...

Страница 11: ...1 Example The audible dialing monitor will be enabled F 8 10 Stop function with Ekey Stop function is selectable in the installer mode the yellow LED is ON see 8 1 entering F D where D 0 stop is disab...

Страница 12: ...or two voice messages can be selected in the installer mode the yellow LED is ON see 8 1 entering F D where D means number of messages 1 1x 20sec or 2 2x 10sec factory default 2 messages max 10sec eac...

Отзывы: