OS-360A / OS-365A outdoor siren
2 / 2
MGZ52200
Control panel wiring examples
If wired according to figure 2, the siren sounds and flashes during the
whole period of control panel alarms. The siren also provides an
acoustic confirmation of system setting/unsetting. The flashing stops
simultaneously with the sound.
JA-80K
OS-365A
01
CO
M
02
NC
NO
EW
-C
IW
PG
X
PG
Y
GN
D
A
B
+U
1k
PGX
function programmed to
ABC/AB/anything set
OK
NC/NO
FLASH
Fig. 2 Connection to the JA-80K control panel
If wired according to figure 3, the siren sounds and flashes during the
whole period of control panel alarms, with the light continuing to flash
for 30 minutes after alarm deactivation. No confirmation of system
setting/unsetting is provided, only a ready-state indication (1x flash in
every 45 sec) which is independent of the system status.
JA-82K
01
02
CO
M
03
04
EW
IW
PGX
PGY
GN
D
A
B
+U
1k
PGX
function programmed to
ABC/AB/anything set
OS-365A
OK
NC/NO
FLASH
Fig. 3 Connection to the JA-82K(R,C) control panel
If wired according to figure 4, the siren sounds and flashes during the
whole period of control panel alarms, with the light continuing to flash
for 30 minutes after alarm deactivation. Both acoustic confirmation of
system setting/unsetting and ready-state indication are provided – 1x
flash in every 45 sec, independently of the system status.
JA-65K
TM
P
TM
P
PG
X
PG
Y
C
NC
NO
GND
SI
R
+U
2k2
OS-365A
OK
NC/NO
FLASH
Fig. 4 Connection to the JA-65K control panel
If wired according to figure 5, the siren sounds and flashes during
power supply faults, with the sound continuing for just 3 more seconds
from the moment the power supply is restored. The flashing continues
for 30 minutes. No confirmation of system setting/unsetting and no
ready-state indication is provided.
JA-63K
OS-365A
L1
L2
CO
M
L3
L4
NO
NC
C
SIR
PGX
PGY
+U
GN
D
OK
NC/NO
FLASH
Fig. 5 A simplified two-wired siren-connection
Maintenance
The siren does not need any special maintenance. The NiCd battery
lifetime is about 3 years, depending on the working conditions.
Specialized auto-recharge mode keeps the battery in optimum state. If
the power supply (+12V and GND) is disconnected for a significantly
long period of time, then also disconnect the battery. It is
recommended to perform siren battery checking within general security
system testing – you can check the battery remotely without any direct
access to the siren.
Note: Whenever you handle any of the terminals (e.g. 12V
disconnection) disconnect the battery to avoid siren activation.
Important: An activation of the siren with a disconnected sounder
(see Fig. 1) does not cause any damage to the electronic circuits.
Instead, a high voltage is produced on the sounder connector.
Specification
Power supply
10 to 15 V DC
Standby consumption
< 50 mA / 12 V
Maximum load consumption
< 800 mA /12 V
Backup battery
NiCd pack 4.8 V / 1800 mAh
Lifetime approx. 3 years
Piezoelectric siren (OS-360) sound level
113 dB / 1 m
With second piezo-electric siren (ACM-OS360)
118 dB / 1 m
Electro-acoustic siren (OS-365) sound level
110 dB / 1 m
Siren timer
max. 5 minutes
Flasher time
alarm du15 minutes / 0
Resistance of the tamper loop
< 70
Ω
Enclosure IP
34D
Security grade 2
EN 50131-1, CLC/TS 50131-4
Working environment
class IV, outdoor general
Operational temperature
-25 to +60°C
EMC
EN 50130-4, EN 55022
Safety EN
60950-1
Dimensions
230 x 158 x 75 mm
Jablotron Ltd. hereby declares that the OS-360A/365A is in
compliance with the essential requirements and other
relevant provisions of Directives 2004/108/EC and
2006/95/EC. The original of the conformity assessment can
be found on the web site
www.jablotron.com
, Technical
Support section.
Note
: The NiCd backup battery contains cadmium (Cd).
Dispose of batteries safely depending on battery type and
local regulations. Although this product does not contain any
harmful materials we suggest you return the product to the
dealer or directly to the manufacturer after use.